Installing the cabinet
To obtain the best performance from the cabinet, ensure :
·the cabinet is placed in a dry, cool place and is not exposed to direct sunlight.
·the cabinet is not placed close to a source of heat, e.g. a cooker or dishwasher.
·the cabinet is level. The cabinet should not lean against any wall. If necessary adjust the
feet using the adjustment spanner supplied.
·there is good air circulation around the cabinet
and that the air channels below and behind the cabinet are not blocked. The ventilation space above the cabinet must be at least 4 cm.
The ventilation space can either be
a)directly above the cabinet, or
b)behind and above the top cupboard. In this case,
the space behind the cupboard must be at least 50 mm deep.
Cabinet is placed at a location whose ambient temperature corresponds to the climate classification*, for which the appliance is designed.
*See on the rating plate on the inside of the appliance.
The following table shows which ambient temperature is correct for each climate classification.
Climate | for an ambient temperature of | |
classification | ||
| ||
SN | +10°C to +32°C | |
|
| |
N | +16°C to +32°C | |
ST | +18°C to +38°C | |
T | +18°C to +43°C |
Check that the drain hose at the rear of the cabinet discharges into the drip tray.
If the cabinet is placed in a corner and the side with the hinges facing the wall, the distance between the wall and the cabinet must be at least 10 mm to allow the door to open enough so that the shelves can be removed.
The power plug must be accessible after installation of the cabinet.
a) | b) | 50mm |
14
Zanussi 818 14