Zanussi ZRT 175W manual Door Reversal, Ventilation Requirements, Levelling

Models: ZRT 175W

1 20
Download 20 pages 56.99 Kb
Page 14
Image 14
Ventilation Requirements

Ventilation Requirements

The appliance must have adequate ventilation to ensure correct operation.

Diagram shows the ventilation requirements when installed:

A* Under a worktop, or cupboard.

*The clearance space of 10 cm above the appliance may be reduced to 5 cm providing a clearance space 2.5 cm is left on either side of the appliance.

B When freestanding

Levelling

The appliance must be level. Level the appliance by adjusting the two adjustable feet (1) at the front of the appliance.

If required the washer (2) can be removed.

Door Reversal

If required the opening direction of the door can be changed as follows:

To reverse the bottom hinge assembly proceed as follows:

Disconnect the appliance from the electricity supply.

Tilt the appliance backwards, resting the top edge of the appliance on a stool or something similar.

Unscrew the adjustable feet situated on both sides (2 pieces), in addition the screws fixing the lower door holders (3 pieces) respectively the screw on the other side.