Zephyr AK2148 Shooting, Upon completion of installation, nothing works, scraping on something

Models: AK2136 AK2142 AK2148 AK2100

1 27
Download 27 pages 15.87 Kb
Page 21
Image 21
1. Upon completion of installation

1. Upon completion of installation

Check if unit has been plugged in, make sure that all power has been

Shooting

 

nothing works.

turned back on and all electrical wiring are properly connected.

 

 

 

 

2. Light is on but blowers are not

Blower blade unit might have been mounted too low and scraping

 

turning at all or seems to be

the bottom or jammed. Loosen hex screw on blade unit and adjust to

 

scraping on something.

proper height.

 

 

 

 

3. When blowers are on,

There might have been foreign particles left within the discharge

Trouble

something seems to be loose

opening or rocks, leaves, branches, etc. that might have fell in from

 

and spinning around inside.

old duct work. Disconnect duct work to inspect and remove any

 

 

foreign particles.

 

 

 

 

4. Vibration when blowers are on

Unit might not have been secured properly on cabinet. Or cabinet

 

 

might need to be further secured into studs on wall.

 

 

 

 

5. Blowers noise

Our blowers are designed to perform up to 850 cfm. A properly

 

 

functioning motor itself should be relatively quiet. Nevertheless, due

 

 

to vacuum created by the suction, noise level up to 6 sones will be

 

 

generated when both blower unit is turned on at its maximum speed.

 

 

Employing low speeds will suffice moderate cooking such as steam-

 

 

ing, broiling etc.

 

 

 

 

6. Light is not working

Light bulb might need to be replaced. On some instances, the fragile

 

 

bulb could have been damaged during the shipping process.

 

 

Replace light bulb.

 

 

 

 

7. No grease is collected in the

Grease flow will vary by the amount, methods and types of cooking.

 

clean cups

If pan-frying is frequent accompanied by steaming, vapor from steam

 

 

will liquefy accumulated grease in its internal housing and flows in

 

 

the clean cups. No grease collected in the residue containers is

 

 

normal until the self clean function is completed. Clean blowers

 

 

approximately once a month as instructed to avoid clogging.

 

 

 

 

8. No grease is collected in

Tubes connected to the internal housing might have been clogged

 

the residue containers after

due to lack of cleaning. Or hood might not have been leveled when

 

self cleaning.

installed. Unclog tubes or re-install hood.

 

 

 

 

9. Safety grill are dirty

The self clean feature cleans only the internal housing within the

 

 

range hood. Remove safety grill to clean in dishwasher and clean all

 

 

surface periodically as instructed.

 

 

 

 

10. Blowers seemed weak

Check duct size used, duct size should be at least 7”. Range hood

 

 

WILL NOT function properly with the insufficient duct size.

 

 

Check if duct is clogged or if dumper unit is not opening properly. A

 

 

tight mesh on a side wall cap unit might also cause restriction to the

 

 

air flow.

 

 

Use a damper type sidewall cap.

 

 

Reduce the number of elbows and length of duct work or increase

 

 

duct size.

 

 

Check if all joints are properly connected, sealed and taped.

 

 

 

 

11. Cooking fumes and smoke

Check if unit is installed at the recommended height. The range hood

 

dissipates before it reaches

should also be able to cover the entire cooking area from left to right

 

the blower.

and most areas from rear to front.

 

 

Open doors and windows might also distract air flow before it reach-

 

 

es the blowers.

 

 

Make sure blowers are on high speed for heavy cooking.

 

 

 

 