PERFORMANCE
The system efficiency depends on the sense resistor, supply voltage, switching inductor, and the number of LEDs.
With a 60V supply and 15 LEDs, the switching frequency is typically 200 kHz and efficiency levels >90% are achievable.
Visit our website www.zetex.com to find useful tools for circuit design and simulation.
REFERENCE
[1] ZXLD1362 Datasheet – www.zetex.com