SNC 5100

 

 

 

 

 

 

 

Table 4-1: Post-Repair Checklist

 

 

 

 

 

 

 

 

Step

Actions

 

Comments and References

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

From the service

 

In the output of the fcShow command, look for the

 

 

 

terminal, enter the

 

Firmware State column.

 

 

 

fcShow command to

 

 

 

 

 

show the status of each

 

If the word Ready does not appear, go to “Fibre

 

 

 

FC interface that is

 

Channel MAP” on page 61.

 

 

 

installed and connected.

 

 

 

 

 

 

 

Check to see that all SCSI target devices are seen by

 

 

 

From the service

 

each FC interface.

 

 

 

terminal, enter the

 

 

 

 

 

fcShowDevs

 

If not, go to “SCSI Channel MAP” on page 50.

 

 

 

command to show the

 

 

 

 

 

SCSI target devices that

 

 

 

 

 

are connected as seen by

 

 

 

 

 

the Fibre Channel

 

 

 

 

 

interface.

 

 

 

 

 

 

 

 

 

 

11

Verify that all (or the

 

Use appropriate host system utilities for tape.

 

 

 

designated) target

 

See Table 4, “Host Utility Software,” on page 23.

 

 

 

devices are available to

 

 

 

 

 

the host systems.

 

If “Access Control” is enabled (Channel Zoning or

 

 

 

 

 

SFM) the hosts will only see the devices that have

 

 

 

 

 

been assigned to them.

 

 

 

 

 

If the designated devices are NOT available, reboot

 

 

 

 

 

the host and check again.

 

 

 

 

 

If the problem persists, go to “Start MAP” on page 42.

 

 

 

 

 

 

 

 

12

Disconnect the RS-232

 

None.

 

 

 

cable from the and from

 

 

 

 

 

the service terminal.

 

 

 

 

 

 

 

 

 

 

13

End of repair.

 

 

 

 

 

 

 

 

 

Post-Repair Checklist

93

6-00020-02

Page 101
Image 101
ADIC SNC 5100, Scalar 1000 manual FcShowDevs