6. Combination Table

6.2 Heat Pump

6.2.1 A2UH146FA0

Cooling

 

 

 

Combination(k Btu)

 

 

 

 

Cooling

 

 

 

Operation

 

 

 

Capacity (Btu/h)

 

Input

Current

EER

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

D

 

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

(W)

(A)

(Btu/h.W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

7

 

-

-

-

 

7

9400

-

-

-

9400

1350

6.1

7.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

7

 

7

-

-

 

14

7200

7200

-

-

14400

1450

6.6

9.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

 

Combination(k Btu)

 

 

 

 

Heating

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity (Btu/h)

 

Input

Current

EER

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

D

 

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

(W)

(A)

(Btu/h.W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

7

 

-

-

-

 

7

10000

-

-

-

10000

1500

7.0

6.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

7

 

7

-

-

 

14

7300

7300

-

-

14600

1300

6.0

11.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.2.2 A2UH186FA0

Cooling

 

 

 

Combination(k Btu)

 

 

 

 

Cooling

 

 

 

Operation

 

 

 

Capacity (Btu/h)

 

Input

Current

EER

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

D

 

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

(W)

(A)

(Btu/h.W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

-

-

-

 

7

7000

-

-

-

7000

780

3.5

9.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

9

 

-

-

-

 

9

9500

-

-

-

9500

1100

5.0

8.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

-

-

-

 

12

11000

-

-

-

11000

1100

5.0

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

7

-

-

 

14

7000

7000

-

-

14000

1900

8.5

7.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

7

 

9

-

-

 

16

7000

9000

-

-

16000

1900

8.5

8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

9

-

-

 

18

9000

9000

-

-

18000

1900

8.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

12

-

-

 

19

7000

11000

-

-

18000

1900

8.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

 

Combination(k Btu)

 

 

 

 

Heating

 

 

 

Operation

 

 

 

Capacity (Btu/h)

 

Input

Current

EER

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

D

 

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

(W)

(A)

(Btu/h.W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

-

-

-

 

7

9000

-

-

-

9000

1300

6.0

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

9

 

-

-

-

 

9

10500

-

-

-

10500

1250

5.6

8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

-

-

-

 

12

12100

-

-

-

12100

1200

5.5

10.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

7

-

-

 

14

7700

7700

-

-

15400

1900

8.5

8.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

7

 

9

-

-

 

16

7700

9900

-

-

17600

1900

8.5

9.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

9

-

-

 

18

9900

9900

-

-

19800

1900

8.5

10.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

12

-

-

 

19

7700

12100

-

-

19800

1900

8.5

10.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2004 Product Data 23

Page 24
Image 24
LG Electronics LM50 2004-E1 manual Heat Pump, Heating, 1 A2UH146FA0, 2 A2UH186FA0