7. Dimensional Drawings
7.1 Indoor Units
AMNC-LQ/LR/LT, AMNH-LQ/LR/LT
H
More than
5cm
D
W
More than 5cm
More than 2.3m |
| More than |
|
|
| 5cm |
|
Installation plate | Note: |
|
|
| 1. Pipe Specification(mm) | ||
| Model | Liquid | Gas |
| 7, 9, 12k | Ø 6.35 | Ø 9.52 |
| 18, 24k | Ø 6.35 | Ø 12.7 |
|
| CHASSIS |
| Distance(mm) |
| ||
C |
| (Grade) | A | B | C | D | |
Installation plate |
| ||||||
D | SQ(7/9k) | 75 | 12 | 80 | 12 | ||
B | |||||||
Ø70mm | A | SR(12k) | 0 | 40 | 20 | 40 | |
| Ø70mm |
|
|
|
| ||
Left rear piping | Right rear piping | ST(18/24k) | 105 | 0 | 210 | 0 |
|
|
| (unit : mm) | |
Model | W | H | D | |
AMNC/H076LQL0 | 824 | 260 | 155 | |
AMNC/H096LQL0 | ||||
|
|
| ||
AMNC/H126LRL0 | 900 | 285 | 156 | |
AMNC/H186LTL0 | 1090 | 314 | 172 | |
AMNC/H246LTL0 | ||||
|
|
|
2004 Product Data 27