3.2Understanding the Operating Parameters

Device Type

You will need to select the device type to “Serial Interface” from Appendix A, Group 1 of Appendix D, or the following label.

Serial Interface

Baud Rate, Parity and Data Bit:

These parameters set the scanner’s communication protocol that must be matched by the host. The default setting for the serial interface is 9600 baud rate, none parity, and 8 data bit.

*Baud Rate can be 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps.

*Parity can be even, odd, space, mark, or none.

*Data Bit can be 7 or 8 bit long.

The scanner may not support settings with Data Bit as 7 and Parity as none combination. Such combination is treated as 7 data bits with MARK parity.

Handshaking:

The scanner supports CTS/RTS handshaking as an option. The hardware handshaking is supported on character-by-character basis.

During the communication, the scanner will stop sending data until the CTS is valid within time specified by the Time Out parameter. During this time-out waiting period:

--If CTS is valid, communication resumes.

--If CTS is not valid, the scanner sounds an error beep and discards the current buffered data.

Page 9

Page 10
Image 10