D.5 Scanner Port:

Enter Group 5

Group Default

0

1

Terminator:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0Enter

1Return (on digits keypad)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Field Exit or Right Ctrl

3None

 

 

 

 

 

 

D1

Code ID:

0 – disable

1 – Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This setting doesn’t affect EAN128 Code ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EAN128 has its own Code ID setting on page D.7.

 

 

 

 

 

 

D2

2

3

Define Code ID:

00–Code 39 Full ASCII

11–MSI Code

01–Code 39 Standard

12– EAN128

02–EAN-13

13–Code32 (Italian

03–UPC-A

harmacy)

04–EAN-8

14–Delta Code

05–UPC-E

15–Label Code

06–Interleaved 2 of 5

16–Plessey Code

07–Codabar

17– Code 11(Special)

08–Code 128

18–China Postal code

09–Code 93

(Toshiba Code)

10–Standard 2 of 5

 

D3

Scan two digits to choose a code, then scan a char. From full ASCII table to define ID.

4

5

6

7

8

9

Double Verification:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 – Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1~7 – On(Verify 1~7 times)

 

 

 

 

 

D4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scanning Mode:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0Trigger Mode

 

1– Flashing Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 –Multiscan Mode

 

3–One Press One Scan

 

 

 

 

 

D5

4-–Test Mode

 

5–Old Laser flash Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Label Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 – Positive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 – Positive and Negative

 

 

 

 

 

D6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aim function for long range laser engine:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0—Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1—Enable

 

 

 

 

 

 

 

 

 

 

 

D7

 

 

 

 

Preamble

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PP

 

 

 

 

Postamble

 

 

 

 

Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OO

Scan ‘PP\OO’ for Pre\Postamble. Scan characters from Full ASCII char or Function

Page D.5

Page 41
Image 41
Unitech Hand Held Scanner user manual Scanner Port, Define Code ID