4. Sample program

5

Specifications

[PLC data assignment]

 

X0 (*1)

: Unit error

X1 (*1)

: Local station data link status

X6 (*1)

: Data link start normal completion

X7 (*1)

: Data link start error completion

X0F (*1)

: Unit ready

X100

: 1st unit’s SO(00): Emergency stop input status

X101

: 1st unit’s SO(01): CPU_OK

:

:

X17F

: 1st unit reservation

X180

: 2nd unit’s SO(00): Emergency stop input status

X181

: 2nd unit’s SO(01): CPU_OK

:

:

X1FF

: 2nd unit reservation

Y0 (*1)

: Refresh instruction

Y6 (*1)

: Data link start request

Y100

: 1st unit’s SI(00): Emergency stop input

Y101

: 1st unit’s SI(01): Servo ON input

:

:

Y17F

: 1st unit reservation

Y180

: 2nd unit’s SI(00): Emergency stop input

Y181

: 2nd unit’s SI(01): Servo ON input

:

:

Y1FF

: 2nd unit reservation

M0

: Unit preparation complete flag

M1

: Parameter setting flag

M2

: Data link start flag

M4

: 1st station data link status

M8

: 5th station data link status

D0

: No. of connection units storage device

D1

: 1st unit local station information setting storage device

D2

: 2nd unit local station information setting storage device

D10

: Parameter setting status storage device

*1: This number is determined by the master module mounting position and the number of occupied input/output points mounted before the module.

5-12

Page 66
Image 66
Yamaha RCX Series, Yamaha Robot Controller CC-Link Unit owner manual PLC data assignment, X1FF