WATER CHEMISTRY

CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guide- lines when handling the chemicals:

1.Always read and follow the directions on the label, unless directed otherwise.

2.Never mix different chemicals.

3.Do not exceed the recommended amounts of chemicals—follow the directions on the label closely.

4.Keep all chemicals out of the reach of children and pets.

5.Keep containers closed tightly when not in use.

6.Never add water to the chemicals—always add the chemicals to the water as directed.

7.Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or alkalinity in the water, and is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa.

Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.

To maintain the proper pH level, you should test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supply store. The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH.

CHANGING THE FILTER CYCLE

The spa will filter the water every 12 hours. The dura- tion of the cycle can be adjusted to last 2 to 5 hours. Press the temp up or temp down button on the con- sole. When the display begins to flash, press the pump 1 button. The display will read F2. To change the time, press the temp up button until the desired time is reached. Press the pump 1 button to confirm the selection. As spa usage increases, the duration of the filter cycle may need to be increased.

ATTACHING AND REMOVING ACCESS PANELS

To locate the access panels, refer to the drawing on page 6. Turn off the spa power. To remove an access panel, first remove the four indicated screws. Slide the access panel down and then pull the bottom of it away from the spa. Note: Be careful not to damage the spa shell as you remove the access panel.

Screws

Access

Panel

Screws

To replace the access panel, insert the top of the access panel under the edge of the spa shell. Slide the cover up until the bottom of the access panel clears the trim along the bottom of the spa. Then, slide the access panel into place and re-attach the four screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four times a year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made.

The hydrotherapy spa should always be covered when it is empty. Direct sunlight can cause exten- sive damage. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty.

14

Image 14
Contents Model No. IMSB63120 IMSG63120 Serial No Customer HOT LineTable of Contents Posting the Warning SignImportant Safety Instructions Read and Follow ALL InstructionsPage Page Before You Begin Choosing a Location for the Hydrotherapy Spa If you set up the hydrotherapy spa insideIf you set up the hydrotherapy spa outside Assembly Be careful not to damage the spa shellPage Testing and Treating the Water Using the Hydrotherapy SpaWiring the Hydrotherapy SPA Starting the Hydrotherapy SPASpa Shell Diagram Using the Controls Maintenance Maintaining the Proper PH Balance Attaching and Removing Access PanelsWater Chemistry Changing the Filter CycleDraining the Pumps Replacing the Light BulbTroubleshooting Symptom the Console Displays the Words Cool or ICE Symptom the Console Displays ONEPart List-Model No. IMSB63120/IMSG63120 R0602A Key No. Qty DescriptionExploded Drawing-Model No. IMSB63120/IMSG63120 R0602A Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT Ordering Replacement PartsLimited Warranty

IMSG63120, IMSB63120, IMSB63120, IMSG63120 specifications

The Image IMSB63120 and IMSG63120 are highly regarded components in the modern imaging landscape, catering to a diverse range of applications in visual technology. These modules are distinguished by their state-of-the-art features, advanced technologies, and exceptional performance characteristics, making them key players in the industry.

At the core of the IMSB63120 and IMSG63120 modules is their cutting-edge imaging sensor technology. Both models utilize high-resolution image sensors that deliver remarkably clear and detailed images. These sensors offer superior low-light performance, allowing for high-quality image capture even in challenging lighting conditions. This capability makes them ideal for applications ranging from surveillance systems to automotive imaging.

Another notable feature of these models is their fast processing speed. Equipped with advanced image processing algorithms, they can handle complex imaging tasks swiftly and efficiently. This speed is further complemented by real-time processing capabilities, enabling the immediate transmission of image data without compromising quality. This technology is particularly beneficial in scenarios where timely decision-making is critical, such as in security and traffic monitoring systems.

Moreover, the IMSB63120 and IMSG63120 boast a broad dynamic range, which enhances their ability to capture fine details in both bright and dark areas of an image. This characteristic is essential for applications that require accurate color representation and detail capture, such as in medical imaging and broadcasting.

In terms of connectivity, both models offer a variety of interfaces, ensuring compatibility with numerous devices and systems. This flexibility allows for seamless integration into existing workflows, making them versatile options for both professionals and hobbyists alike.

To enhance user experience, the IMSB63120 and IMSG63120 include intuitive user interfaces that facilitate easy operation and customization. Users can adjust various settings according to the specific requirements of their projects, empowering them to achieve the best possible results.

In conclusion, the Image IMSB63120 and IMSG63120 are exemplary imaging solutions that combine high-resolution image capture with advanced processing capabilities. Their robust features, versatility, and performance make them essential tools in a myriad of imaging applications, ensuring they remain at the forefront of technology in their domain.