Image IMSG61502,IMSB61502, IMSB61502, IMSG61502 user manual

Page 9

3.Locate the three pillows. Each pillow can be attached to the spa shell in a high position or a low position. To determine the high and low positions, attach one pillow to the spa shell, note its position, remove it, turn it 180°, and then re-attach it. Attach the three pillows in the desired positions.

3

Pillow

 

Pillow

Pillow

4.The spa operates on a 240-volt power source and must be wired directly to a 30 amp Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed electrician. A wiring diagram has been provided on the inside of the electronics package as a reference. Under no circumstances should the spa be wired by someone other than a qualified electrician. Before you have the spa wired, make sure that it is in the desired position and that it can be serviced, if needed.

5.Remove the two warning decals (not shown) from the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to service the spa. Once the spa is filled, it will have to be drained before it can be moved.

Insert a garden hose into the filter housing, and begin filling the spa. Do not use soft water. The spa may be filled with cold water; however, if warm or hot water is used, the spa will be ready for use sooner. Fill the spa until the water is at the level of the molded fill line. Do not overfill the spa.

Refer to the inset drawing. Set the Filter (16) in the filter housing. Screw the Filter Cover (8) into the fil- ter housing until it is fully seated.

6.Pull down one of the straps on the Spa Cover (11) and hold the Buckle (30) against one of the cedar panels on the spa. (Note: To position the Buckle cor- rectly, have a second person hold the strap on the opposite side of the Spa Cover tight.) The Spa

Cover must be tight. Do not place the Buckle over the grooves between the cedar panels. Refer to the inset drawing. Remove the latch from the Buckle (30). Attach the Buckle to the cedar panel with two #4 x 3/4” Screws (31).

Attach the other three Buckles (30) to the cedar pan- els in the same way.

Remove the Spa Cover (11) from the spa.

5

 

8

 

 

16

 

Molded

Filter

 

Housing

 

Fill Line

 

 

 

Filter

 

 

Housing

 

6

 

 

 

11

Strap

 

 

 

 

Latch

 

 

30

 

 

31

 

 

Strap

 

 

30

9

Image 9
Contents Customer HOT Line Model No. IMSB61502 IMSG61502 Serial NoPosting the Warning Sign Table of ContentsRead and Follow ALL Instructions Important Safety InstructionsPage Page Before You Begin If you set up the hydrotherapy spa inside If you set up the hydrotherapy spa outsideChoosing a Location for the Hydrotherapy Spa Spa. Be careful not to damage the spa shell AssemblyPage Wiring the Hydrotherapy SPA Using the Hydrotherapy SpaTesting and Treating the Water Securing the SPA Cover on the SPASpa Shell Diagram Using the Controls Maintenance Water Chemistry Attaching and Removing Access PanelsMaintaining the Proper PH Balance Changing the Filter CycleReplacing the Light Bulb Draining the PumpTrouble-shooting Symptom the Console Displays ONE Symptom the Console Displays the Words Cool or ICEKey No. Qty Description Part List-Model No. IMSB61502/IMSG61502Exploded Drawing-Model No. IMSB61502/IMSG61502 R0901A Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT