TROUBLESHOOTING | ||
Observe all Safety Guidelines detailed throughout this manual | ||
PROBLEMS | POSSIBLE | RECOMMENDED |
(SYMPTOMS) | CAUSE | COURSE OF ACTION |
OUTPUT PROBLEMS
| Machine is Dead | 1. | Make certain that the input power | |
| Fan |
| switch is in the “ON” position and | |
|
|
| machine is plugged in. | |
|
| 2. | Check the input voltage at the | |
|
|
| machine. Input voltage must | |
|
|
| match the rating plate and volt- | |
|
|
| age connection. Refer to | |
|
|
| Reconnect Procedure in the | |
|
|
| Installation section of this manual. | |
|
| 3. | Blown or missing fuses in input | |
|
|
| line. | |
|
|
|
|
|
| Fan runs normally at power up - No | 1. | Check for proper input voltages | |
| output from machine in either Stick |
| per nameplate and voltage recon- | |
| or TIG modes. |
| nection. | |
|
| 2. | Check to make sure polarity | |
|
|
| switch is not in between two posi- | |
|
|
| tions. | |
|
|
|
| |
| Fan runs - No output from machine | 1. | Welding application may have | |
| in either Stick or TIG modes and the |
| exceed the recommended duty | |
| yellow light on the control panel is |
| cycle. Allow the unit to run until | |
| on. |
| the fan cools the unit and the yel- | |
|
|
| low light goes out. | |
|
|
| ||
| Machine does not respond (no gas | 1. Machine MUST be in the TIG | ||
| flow, no high frequency and no open |
| Mode. | |
| circuit voltage) when arc start switch | 2. | The Amptrol may be defective. | |
| or Amptrol is activated - fan is work- |
| Check for continuity between pins | |
| ing. |
| “D” and “E” on cable connector | |
|
|
| when Amptrol is depressed. | |
|
|
|
|
|
|
|
|
|
|
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
![]()
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your