TROUBLESHOOTING | ||||
Observe all Safety Guidelines detailed throughout this manual | ||||
|
|
|
|
|
PROBLEMS |
| POSSIBLE | RECOMMENDED | |
(SYMPTOMS) |
| CAUSE | COURSE OF ACTION | |
|
| OUTPUT PROBLEMS |
|
|
Machine regularly over heats - the- | 1. | Welding application may exceed |
|
|
mostat opens, Yellow light on front |
| recommended duty cycle. Reduce |
|
|
panel glows. The fan runs but |
| the duty cycle. |
|
|
machine has no output. |
|
|
|
|
| 2. | Dirt and dust may have clogged |
|
|
|
| the cooling channels inside the |
|
|
|
| machine. Blow out unit with clean, |
|
|
|
| dry low pressure air. |
|
|
| 3. | Air vents and exhaust louvers may |
|
|
|
| be blocked due to inadequate |
|
|
|
| clearance around machine. |
|
|
|
|
|
|
|
Output current reduced significantly | 1. | Input power to machine doesnʼt |
|
|
when AC Balance control knob is set |
| have sufficient capacity. Try |
|
|
near or at max. penetration or when |
| changing Input power to a suffi- |
|
|
Output control is set near or at full |
| cient supply, refer to Installation |
|
|
output. |
| section. |
|
|
| 2. Machine is powered from an |
|
| |
|
| engine generator or an engine | If all recommended possible areas of | |
|
| welder. If welding at high currents | misadjustment have been checked | |
|
| are needed, try powering machine | and the problem persists, Contact | |
|
| from electricity grid instead of | your local Lincoln Authorized | |
|
| engine generator. | Field Service Facility. | |
| 3. | Set AC Balance control at Auto |
|
|
|
| Balance position. |
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION