INSTALLATION CONFIGURATIONS
The Multifuel Heater Model 6041TP/6041HF may be installed as follows:
1)A freestanding unit
The Multifuel Heater Model 6041I insert may be installed as follows:
1)In a
2)In an existing masonry fireplace
3)As a
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
WARNING
DO NOT INSTALL IN SLEEPING ROOM
1)Heater must be permanently bolted to the floor. Remove the Base Trim and bolt thru the base flange.
2)Heater must have permanent outside air source. (69FAK)
3)Heater must be permanently electrically grounded to the steel chassis of the mobile home.
4)All vertical chimney vent must have wall supports.
5)All exhaust systems must have a spark arrestor.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
Check with your local building official as other codes may apply.