Maintenance Instructions
Coil Descaling
In hard water areas, scale
1.Mix coil cleaner in a 5 gallon bucket and elevate the bucket so it is higher than the unloader.
2.Attach the
3.Place the other end of the
4.Attach a short length of hose to the garden hose inlet on the pump.
5.Prime the pump by filling the hose with water, then place the end of the hose in the bucket.
6.Run the pressure washer in cold mode for 1 to 3 hours
Warning: Do not run the burner.
7.Dispose of the cleaning solution where it is not harmful to animals or the environment.
8.Flush with fresh water and clean the inlet strainer when finished.
Coil Desooting
Poor grades of fuel oil or inadequate combustion air will cause heavy soot
Most coils will never require desooting. However, to desoot a coil...
1.Wear protective clothing, goggles, and gloves.
2.Disconnect
3.Remove the lid and insulation lid from the heating chamber and hoist the coil out. Be careful, the coil weighs 125 lbs.
4.Clean the coil.
5.Reassemble the coil to the machine. Make sure the white insulation remains in place.
6.Reattach
11