P3 International E 9300 Calling up configuration mode, Setting the date and time

Page 10

In configuration mode the keys have the following functions:

IN

not used

 

SENSOR

EXIT

Leave configuration mode

MIN/MAX

+

Increase value

RAIN

Decrease value

OUT

NEXT

To the next setting

This key assignment is also shown on the rear of the weather station.

Please note!

If you press and hold down the "+" or "-" keys during the individual setting opera- tions, the figures will run through more quickly.

After every setting operation you can either leave configuration mode by pressing the "EXIT" key or proceed to the next setting via the "NEXT" key.

Configuration is performed in this order:

Year Month Date Minutes Hours Daylight saving timeDeg. latitude (LA) Deg. longitude (LO) Time zone (ti) Rain sensor calibrationRain quantity unit Assignment of indicator path Wind unit

IN

[2 seconds]

+

Year

Calling up configuration mode

Configuration mode is called up by pressing the "IN" key for about 2 seconds. When the key is released the corresponding display is shown.

You can leave configuration mode at any time as described in "Leaving configuration mode".

Setting the date and time

Set the current year using the "+" and "-" keys.

NEXT

 

 

Press "NEXT" to go to the month setting.

+

Month

Set the month using the "+" and "-" keys.

NEXT

 

 

Press "NEXT" to go to the date setting.

10

Image 10
Contents Professional Weather Station E Page Contents Display of the wind speed Display of the indoor temperature and humidityGeneral information and functions Display of the amount of rainfall in mm, l/m2 or inch forDisplay of the change / trend in air pressure Moon phase displayWeather Wiz Kid display Quick overview of the main display fields Preparation for operation Commissioning 93019305 Base unitSetting up/Wall mounting OperationCalling up configuration mode Setting the date and timeSetting the status of the daylight saving time Entering latitude and longitudeSetting the time zone EXITQuit Setting the unit for rainfall measurementEntering the rain sensor calibration value Setting the unit for wind speed Assigning the indicator path History displayLeaving configuration mode Resetting the total rainfall quantity Selecting the indoor temperature displaySelecting the outdoor temperature display OperationCalling up maximum values Calling up MIN/MAX valuesCalling up minimum values Deleting MIN/MAX valuesOther display options Wind symbol display wind sock Additional functions Moon phase displayOutdoor temperature combi-sensor only Wiz KidPlease dispose of dead batteries properly Comfort indicatorChanging batteries Base station Instant rain displayTroubleshooting Transmitter batteries are dischargedCleaning the rainfall sensor Maintenance and servicing informationRange Attach Turn to the right Rainfall sensor correctly installed Calibrating the rain sensor Perceived temperature see Wind chill Technical dataExplanation of terms Calm Intended usage, exclusion of liability, safety instructions FCC InformationPage Appendix a Table of latitude/longitude for US counties State County LatitudePage Page Ware County Page Page Page Page Page Page Page Page Page Page Page Page Page Page Time Zone Major Cities Symbol Difference From UTC Appendix B Table of time zone difference from UTCAppendix C Service and Warrenty information P3 International Corporation Limited WarrantyTel
Related manuals
Manual 48 pages 36.75 Kb

E 9300 specifications

The P3 International E 9300 is an innovative energy monitoring device designed to help users take control of their energy consumption while promoting sustainable practices. This compact and user-friendly device caters to both residential and small commercial environments, making it an indispensable tool for anyone looking to reduce energy costs and environmental impact.

One of the standout features of the P3 International E 9300 is its ability to provide real-time energy usage data. The device tracks and displays information on the electricity consumption of connected appliances, enabling users to identify energy-hogging devices and make informed decisions about their usage. The large, easy-to-read LCD screen showcases important details such as voltage, wattage, amp draw, and kilowatt-hour readings, presenting a comprehensive picture of energy usage at a glance.

Incorporating advanced technologies, the P3 International E 9300 utilizes accurate sensors to ensure precise measurements. This reliability is essential for users striving to monitor their energy consumption closely. The device also features a programmable timer, which allows users to set specific intervals for appliances to be powered on or off, further maximizing energy savings. This feature is particularly beneficial for items like lights and heaters that can be managed to reduce unnecessary energy use during off-peak hours.

Another notable characteristic of the E 9300 is its plug-and-play design, which simplifies the setup process. Users can effortlessly connect the device to a standard outlet and begin monitoring their energy consumption immediately. The compact design ensures it doesn't occupy excessive space, making it a convenient addition to any area of the home or office.

For those interested in long-term energy savings, the P3 International E 9300 supports energy budgeting through its cumulative energy usage readouts. Users can track their electricity consumption over time and compare it to their set energy budgets, helping them make adjustments as needed.

Overall, the P3 International E 9300 stands out as an essential tool for conscious consumers looking to optimize their energy use. Its insightful features, accurate tracking capabilities, and user-friendly design position it as an asset for achieving greater energy efficiency and contributing to a more sustainable future. With the P3 International E 9300, users gain valuable insights into their energy habits, empowering them to make meaningful change.