Possible faults that could impair the correct display of the transmitted readings are:

No reception – The distance between transmitter and receiver is too great. Reduce the distance between the transmitter and the receiver.

No reception – Dense shielding materials are positioned between the trans- mitter and the receiver (thick walls, reinforced concrete, ...)

Find another position for the transmitter and receiver. See also chapter 6 ("Range").

Transmitter batteries are discharged.

Change batteries

Transmitter is blocked by a source of interference (radio device, radio headset/loudspeaker)

Remove source of interference or find alternative location for transmitter and receiver. Often the interference is of a temporary nature (radio telephony) or can be removed very easily. If there are radio headsets, baby listening devices or similar devices operating on 433 MHz in your house or in the neighbourhood, their turn-on time is normally limited. Most of these devices permit change to a frequency free of inter- ference. A measure such as this effectively cuts out interference.

A radio sensor interferes with other devices in the 433 MHz range

The transmissions from a radio sensor can interfere with other devices on the same channel for a short period (every 3 minutes for about 100 ms).

Further information on installation and removal of interference

Under critical reception conditions the sensor test mode makes it easier to choose the best possible location. For this purpose, the sensor concerned is put in test mode, so that every four seconds a data packet is transmitted.

To activate the test mode, remove the batteries from the sensors and then wait for at least 60 seconds before putting them back in. You must then initiate synchroni- sation mode on the base unit, also by removing and then reinserting the batteries (Attention! All settings and collected data will then be lost!)

Rotate the weather station a little if required, and if reception is bad, locate it away from electric motors, electrical machines, televisions, computer monitors and large metal surfaces.

To facilitate commissioning you can initially locate the sensors in the vicinity of the base unit (at least 6 ft. distance). In this way you can check the correct transmission of data by the sensor.

19

Image 19
Contents Professional Weather Station E Page Contents Display of the amount of rainfall in mm, l/m2 or inch for Display of the indoor temperature and humidityGeneral information and functions Display of the wind speedDisplay of the change / trend in air pressure Moon phase displayWeather Wiz Kid display Quick overview of the main display fields Commissioning 9301 Preparation for operationBase unit 9305Operation Setting up/Wall mountingSetting the date and time Calling up configuration modeEntering latitude and longitude Setting the status of the daylight saving timeSetting the time zone EXITQuit Setting the unit for rainfall measurementEntering the rain sensor calibration value Setting the unit for wind speed Assigning the indicator path History displayLeaving configuration mode Operation Selecting the indoor temperature displaySelecting the outdoor temperature display Resetting the total rainfall quantityDeleting MIN/MAX values Calling up MIN/MAX valuesCalling up minimum values Calling up maximum valuesWiz Kid Additional functions Moon phase displayOutdoor temperature combi-sensor only Other display options Wind symbol display wind sockInstant rain display Comfort indicatorChanging batteries Base station Please dispose of dead batteries properlyTransmitter batteries are discharged TroubleshootingCleaning the rainfall sensor Maintenance and servicing informationRange Attach Turn to the right Rainfall sensor correctly installed Calibrating the rain sensor Perceived temperature see Wind chill Technical dataExplanation of terms Calm FCC Information Intended usage, exclusion of liability, safety instructionsPage State County Latitude Appendix a Table of latitude/longitude for US countiesPage Page Ware County Page Page Page Page Page Page Page Page Page Page Page Page Page Page Appendix B Table of time zone difference from UTC Time Zone Major Cities Symbol Difference From UTCP3 International Corporation Limited Warranty Appendix C Service and Warrenty informationTel
Related manuals
Manual 48 pages 36.75 Kb

E 9300 specifications

The P3 International E 9300 is an innovative energy monitoring device designed to help users take control of their energy consumption while promoting sustainable practices. This compact and user-friendly device caters to both residential and small commercial environments, making it an indispensable tool for anyone looking to reduce energy costs and environmental impact.

One of the standout features of the P3 International E 9300 is its ability to provide real-time energy usage data. The device tracks and displays information on the electricity consumption of connected appliances, enabling users to identify energy-hogging devices and make informed decisions about their usage. The large, easy-to-read LCD screen showcases important details such as voltage, wattage, amp draw, and kilowatt-hour readings, presenting a comprehensive picture of energy usage at a glance.

Incorporating advanced technologies, the P3 International E 9300 utilizes accurate sensors to ensure precise measurements. This reliability is essential for users striving to monitor their energy consumption closely. The device also features a programmable timer, which allows users to set specific intervals for appliances to be powered on or off, further maximizing energy savings. This feature is particularly beneficial for items like lights and heaters that can be managed to reduce unnecessary energy use during off-peak hours.

Another notable characteristic of the E 9300 is its plug-and-play design, which simplifies the setup process. Users can effortlessly connect the device to a standard outlet and begin monitoring their energy consumption immediately. The compact design ensures it doesn't occupy excessive space, making it a convenient addition to any area of the home or office.

For those interested in long-term energy savings, the P3 International E 9300 supports energy budgeting through its cumulative energy usage readouts. Users can track their electricity consumption over time and compare it to their set energy budgets, helping them make adjustments as needed.

Overall, the P3 International E 9300 stands out as an essential tool for conscious consumers looking to optimize their energy use. Its insightful features, accurate tracking capabilities, and user-friendly design position it as an asset for achieving greater energy efficiency and contributing to a more sustainable future. With the P3 International E 9300, users gain valuable insights into their energy habits, empowering them to make meaningful change.