Porter-Cable H650IS-W instruction manual Storage, Engine Preparation, Generator

Page 17

STORAGE

If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage.

Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach

an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances.

ENGINE PREPARATION

1.Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.

2.Run engine at least 10 minutes after adding stabilizer to allow it to enter the fuel system.

3.Next shut off engine.

4.Disconnect the spark plug wire and remove the spark plug.

5.Add one teaspoon of oil through the spark plug hole.

6.Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber.

7.Replace the spark plug, but do not connect the spark plug wire.

NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and carburetor to prevent gum deposits from forming on these parts and causing possible malfunction of the engine.

GENERATOR

Clean the generator as outlined in the Maintenance Section on this manual.

Check that cooling air slots and openings on generator are open and unobstructed.

17- ENG

D28453

Image 17
Contents Generator Read and understand all safety warnings Consumer General and Service InformationConsumer Safety Information Important Safety Instructions Safety Guidelines / DefinitionsWhen installing a Double Risk of Electrocution and FireRisk of Electrocution and Fire When damagedOperation Generator in rainConfined Area Risk of FireUnit Indoors or in ANY Risk of Unsafe Operation Risk of Breathing Inhalation HazardRisk of HOT Surfaces H650IS-W SpecificationsRisk of Moving Parts Risk from LiftingRemove Generator from Carton AssemblyOther Loose Parts Grounding the GeneratorExtension Cord Wire Gauge Chart Length Size Amperage Double Throw Transfer SwitchObtaining Electricity from the Generator Extension CordsOperation Gas 12V DC OutletBefore Start UP To Start the Engine Stopping Engine Connecting Electrical LoadsConnecting Procedure for Raising or Suspending Generators Maintenance Generator StorageEngine Preparation Running Watts Starting Watts Wattage CalculationsDetermining Wattage Requirements Volts X Amp = Watts Example 120 volts x 10 amps = 1200 watts Starting Wattage RequirementsAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideYear Limited WarrantyENG D28453 Quick Facts