search for remote sensor signals, press [MEMORY] and [CHANNEL] simultaneously.

If that fails, check if the remote sensor is still in place. Make sure the transmission is within range and the path is clear of obstacles and interference.

Repeat this procedure whenever you find discrepancies between the display on the main unit and the display on the remote sensor.

NOTE ON °C AND °F

The outdoor temperature display on the main unit is dominated by the selection on the °C/°F slide switch of the main unit. Whatever the display unit of the remote sensor is, it will only apply to the remote sensor itself and the temperature will be automatically converted to the chosen one of the main unit.

MAXIMUM AND MINIMUM

TEMPERATURES & HUMIDITIES

The maximum and minimum recorded temperatures and humidities will be automatically stored in memory. To display them, press [MEMORY]. Press [MEMORY] again to alternate between the maximum, minimum and current readings. The respective MAX or MIN indicator will be displayed.

To clear the memory, press [MEMORY] and hold for three seconds. The maximum and minimum recorded readings will be erased. Subsequently, if you press [MEMORY] after the memory has been erased, the maximum and minimum readings will have the same values as the current ones.

GB

TEMPERATURE & HUMIDITY TREND

The temperature and humidity trend indicator shows the trend of temperatures and humidities collected at that particular sensor. Three trends: rising, steady, and falling will be shown.

Arrow

 

 

 

indicator

 

 

 

Temperature

R i s i n g

Steady

Falling

Trend

 

 

 

Arrow

 

 

 

indicator

 

 

 

Humidity

R i s i n g

Steady

Falling

Trend

 

 

 

ATMOSPHERIC PRESSURE

The atmospheric pressure arrow indicator will indicate if the atmospheric pressure is increasing, remaining stable, or decreasing.

Arrow

 

 

 

indicator

 

 

 

Pressure

R i s i n g

Steady

Falling

Trend

 

 

 

9

Image 9
Contents Introduction GB Features Main Unit B3. Memory Button D1. Battery CompartmentB4. Channel Button B5. Snooze / Light ButtonFeatures Remote THERMO-HYGRO Sensor D8. Reset ButtonD5. Zone Button Battery Installation Main Unit Before YOU Begin Installing the Table StandBattery door Wall-mount holder Removable table standFollow these steps to install / replace batteries GB Battery and Channel Installation Remote UnitLCD and KEY-PANEL Backlight About Radio ReceptionChart Indicating Radio Signal Strength HOW to Manually SET the ClockAlarm and Snooze Function GB HOW to SET and Activate the AlarmChecking Indoor and Remote Temperatures & Humidities To set the AlarmTemperature & Humidity Trend Maximum and Minimum Temperatures & HumiditiesArrow Indicator Pressure S i n g Steady Falling Trend Atmospheric PressureHOW to Check Barometric Pressure Comfort Level IndicatorsIndicator Temperature Humidity Shows that Displays GB Weather ForecastLOW Battery Indication HOW to Wall Mount or USE Table Stand Remote UnitHOW to Wall Mount or USE Table Stand Main Unit Maintenance GB HOW to Reset the UnitSpecifications Indoor Temperature measurementPower Temperature measurementWeight DimensionsWarranty Customer AssistanceFCC

BAR898HGA specifications

The Oregon Scientific BAR898HGA is a sophisticated weather station designed for both enthusiasts and everyday users who desire accurate and reliable weather information. Its sleek design and modern features make it an essential tool for tracking local weather conditions. One of the standout characteristics of the BAR898HGA is its ability to provide comprehensive weather data, including temperature, humidity, barometric pressure, and forecast trends.

Equipped with advanced sensors, the BAR898HGA delivers precise readings for indoor and outdoor environments. The device features a wireless remote sensor that can be placed outside to capture real-time weather data. This sensor sends data to the base station, which displays information on a clear, easy-to-read LCD screen. Users can effortlessly switch between indoor and outdoor temperature readings, which are displayed in either Celsius or Fahrenheit, catering to user preferences.

In addition to temperature, the BAR898HGA offers humidity monitoring, providing users with insights on the moisture content in the air. This is especially beneficial for those concerned with maintaining healthy indoor air quality or managing home gardening environments. The device also features a barometric pressure sensor, which can help in predicting short-term weather changes. This capability is further enhanced by its built-in weather forecast function, which uses trends in barometric pressure to predict weather conditions, displayed through intuitive weather icons.

Another highlight of the BAR898HGA is its alarm clock functionality, making it a versatile addition to any bedroom or office space. Users can enjoy the convenience of setting alarms, making the device not just a weather station, but a practical everyday tool.

Power management is also considered with this model, featuring a low-battery indicator to inform users when it’s time to change batteries, ensuring that the station operates optimally without unexpected shutdowns.

Overall, the Oregon Scientific BAR898HGA combines reliability, technology, and user-friendly design, making it an excellent choice for anyone interested in monitoring weather conditions accurately and effectively. Its extensive features support a wide range of applications, from gardening to planning outdoor activities, solidifying its place as a must-have weather monitoring device. Whether you're a hobbyist or a practical user, the BAR898HGA stands out as a reliable companion for weather awareness.