GB HOW TO RESET THE UNIT

The [ RESET ] button allows you to return all settings to factory values. Accessing the slot is required only when the unit is not operating in a favorable way such as in the rare case of a malfunction.

The [ RESET ] slot is located inside the battery compartment door. To use the button:

1.Open the battery compartment door.

2.Place a blunt stylus into the hole and press.

3.Close the battery compartment door.

MAINTENANCE

When handled properly, this unit is engineered to give you years of satisfactory service. Here are a few product care instructions:

1.Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth.

2.Do not clean the unit with alcohol containing detergent, abrasive or corrosive materials. Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit.

3.Do not subject the unit to excessive: force, shock, dust, temperature, or humidity. Such treatment may result in malfunction, a shorter electronic life span, damaged batteries, or distorted parts.

4.Do not tamper with the unit's internal components. Doing so will terminate the unit's warranty and may cause damage. The unit contains no user-serviceable parts.

5.Only use new batteries as specified in this instruction manual. Do not mix new and old batteries as the old batteries may leak.

6.Read this instruction manual thoroughly before operating the unit.

SPECIFICATIONS

Main unit

Indoor Temperature measurement

Proposed operating range

: -5.0°C to +50.0°C

 

(23.0°F to 122.0°F)

Temperature resolution

: 0.1°C (0.2°F)

Relative Humidity measurement

Measuring Range

: 25% RH to 95% RH

 

at 25°C (77°F)

Humidity Resolution

: 1% RH

Remote unit

RF Transmission Frequency

: 433 MHz

No. of Remote unit

: Up to 3 units

RF Transmission Range

: Up to 100 meters or 300 feet

Data sensing cycle

: around 40 seconds

12

Image 12
Contents Introduction GB Features Main Unit D1. Battery Compartment B3. Memory ButtonB4. Channel Button B5. Snooze / Light ButtonFeatures Remote THERMO-HYGRO Sensor D8. Reset ButtonD5. Zone Button Before YOU Begin Installing the Table Stand Battery Installation Main UnitBattery door Wall-mount holder Removable table standGB Battery and Channel Installation Remote Unit Follow these steps to install / replace batteriesLCD and KEY-PANEL Backlight About Radio ReceptionHOW to Manually SET the Clock Chart Indicating Radio Signal StrengthGB HOW to SET and Activate the Alarm Alarm and Snooze FunctionChecking Indoor and Remote Temperatures & Humidities To set the AlarmMaximum and Minimum Temperatures & Humidities Temperature & Humidity TrendArrow Indicator Pressure S i n g Steady Falling Trend Atmospheric PressureComfort Level Indicators HOW to Check Barometric PressureIndicator Temperature Humidity Shows that Displays GB Weather ForecastLOW Battery Indication HOW to Wall Mount or USE Table Stand Remote UnitHOW to Wall Mount or USE Table Stand Main Unit GB HOW to Reset the Unit MaintenanceSpecifications Indoor Temperature measurementTemperature measurement PowerWeight DimensionsWarranty Customer AssistanceFCC

BAR898HGA specifications

The Oregon Scientific BAR898HGA is a sophisticated weather station designed for both enthusiasts and everyday users who desire accurate and reliable weather information. Its sleek design and modern features make it an essential tool for tracking local weather conditions. One of the standout characteristics of the BAR898HGA is its ability to provide comprehensive weather data, including temperature, humidity, barometric pressure, and forecast trends.

Equipped with advanced sensors, the BAR898HGA delivers precise readings for indoor and outdoor environments. The device features a wireless remote sensor that can be placed outside to capture real-time weather data. This sensor sends data to the base station, which displays information on a clear, easy-to-read LCD screen. Users can effortlessly switch between indoor and outdoor temperature readings, which are displayed in either Celsius or Fahrenheit, catering to user preferences.

In addition to temperature, the BAR898HGA offers humidity monitoring, providing users with insights on the moisture content in the air. This is especially beneficial for those concerned with maintaining healthy indoor air quality or managing home gardening environments. The device also features a barometric pressure sensor, which can help in predicting short-term weather changes. This capability is further enhanced by its built-in weather forecast function, which uses trends in barometric pressure to predict weather conditions, displayed through intuitive weather icons.

Another highlight of the BAR898HGA is its alarm clock functionality, making it a versatile addition to any bedroom or office space. Users can enjoy the convenience of setting alarms, making the device not just a weather station, but a practical everyday tool.

Power management is also considered with this model, featuring a low-battery indicator to inform users when it’s time to change batteries, ensuring that the station operates optimally without unexpected shutdowns.

Overall, the Oregon Scientific BAR898HGA combines reliability, technology, and user-friendly design, making it an excellent choice for anyone interested in monitoring weather conditions accurately and effectively. Its extensive features support a wide range of applications, from gardening to planning outdoor activities, solidifying its place as a must-have weather monitoring device. Whether you're a hobbyist or a practical user, the BAR898HGA stands out as a reliable companion for weather awareness.