Oregon Scientific BAR210U specifications Overview LCD Display, Back View, Bottom View, SET Clock

Page 1

Weather Light

Model: BAR210 / BAR210U / BAR210A

USER MANUAL

EN

OVERVIEW

LCD DISPLAY

1

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

 

 

 

 

 

6

 

 

 

1.Weather forecast icons

2.Clock signal reception indicator

3.Time / temperature display

4.Outdoor sensor communication indicator

5.Low battery indicator

6.Time zone offset display

BACK VIEW

1

2

1.Ventilation hole

2.Adaptor socket

BOTTOM VIEW

1

4

 

2

5

3

 

 

6

1. / : Increase / decrease setting; activate / deactivate clock reception signal

2. RESET: Reset unit to default settings

3. AUTO ON / OFF: Select auto toggle mode

4. CLOCK: Set time and display mode

5. °C / °F: Select temperature unit and display mode

6. Battery compartment

REMOTE SENSOR

3.Battery compartment

4.RESET hole

5.CHANNEL switch

GETTING STARTED

POWER SUPPLY

Batteries serve as back up power supply for the clock. For continuous use of LCD backlight, always plug in the adapter socket. Make sure the socket outlet is easily accessible to the unit.

To insert batteries:

1.Remove the battery compartment and insert the batteries, matching the polarities.

2.Press RESET after each battery change.

indicates main unit batteries are low.

REMOTE SENSOR

The main unit can be connected to only 1 remote sensor.

To set up the outside sensor:

1.Open the battery compartment.

2.Select a channel then press RESET.

3.Close the battery door.

4.Place the outside sensor within 30 m (98 ft) of the main unit using the table stand or wall mount.

TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.

NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.

SENSOR DATA TRANSMISSION

The main unit will automatically search for the outdoor sensor. The sensor reception icon in the remote sensor area shows the status:

ICON

DESCRIPTION

 

Main unit is searching for

 

sensor.

 

A channel has been found.

 

 

 

Sensor data received.

 

 

and --.-

The sensor cannot be

found.

NOTE If the sensor is not found, check the batteries, obstructions and remote sensor location.

For best results:

Place the sensor out of direct sunlight and rain.

Position the sensor facing the main unit, minimizing obstructions.

Place the sensor in a location away from metallic or electronic objects.

Position the sensor close to the main unit during cold winter months.

CLOCK

CLOCK RECEPTION

This product is designed to synchronize its clock automatically with a clock signal.

BAR210:

EU: DCF-77 signal: within 1500 km (932 miles) of

Frankfurt, Germany.

BAR210U:

UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England.

BAR210A:

WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado.

STRONG

WEAK SIGNAL

NO SIGNAL

SIGNAL

 

 

 

 

 

SET CLOCK

To set the clock manually, disable the signal reception

rst.

1.Press and hold CLOCK.

2.Press or to change the settings.

3.Press CLOCK to confi rm.

4.The settings order is: time zone offset, 12/24 hr format, hour and minute.

BAR210 / BAR210U: Time zone offset sets the clock +/- 23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone offset.

BAR210A: Select the time zone: (P) Pacifi c, (E) Eastern,

(C) Central or (M) Mountain.

CHANGE DISPLAY

To change to auto toggle mode (clock > outdoor tem- perature > indoor temperature), slide AUTO ON / OFF to ON.

To manually toggle between time and temperature displays, press CLOCK or wave your hand at least 3 inches or less from the motion sensor located on the top of the main unit.

NOTE Auto toggle mode and motion sensor will be disabled if a button is pressed, but will be enabled again if no button is pressed for 5 seconds.

NOTE The installed CDS light sensor inside the unit will activate automatic LCD dimming.

WEATHER FORECAST

This product forecasts the next 12 to 24 hours of weather.

ICON

 

 

 

 

 

 

 

COLOR

Red

Green

Blue

MEANING

Sunny

Cloudy

Rainy

TEMPERATURE

To display temperature mode or select temperature unit:

Press °C / °F.

NOTE Please keep the temperature sensor (adjacent to the adaptor socket) away from electrical devices as heat from these devices will affect accurate indoor temperature readings.

RESET

Press RESET to return to the default settings.

PRECAUTIONS

Do not subject the unit to excessive force, shock, dust,

 

temperature or humidity.

Do not cover the ventilation hole with any items such

 

as newspapers, curtains etc.

Do not immerse the unit in water. If you spill liquid over

 

it, dry it immediately with a soft, lint-free cloth.

Do not clean the unit with abrasive or corrosive

 

materials.

Do not tamper with the unit’s internal components. This

 

invalidates the warranty.

Only use fresh batteries. Do not mix new and old

treatment is necessary.

Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before fi rst use.

NOTE The technical specifi cations for this product and the contents of the user manual are subject to change without notice.

SPECIFICATIONS

TYPE

DESCRIPTION

MAIN UNIT

 

L x W x H

70 x 80 x 206 mm

(2.76 x 2.76 x 8.11 in)

 

Weight

235 g (8.3 oz)

without battery

 

 

 

Indoor Temperature range

-5°C to 50°C

(23°F to 122°F)

 

 

 

Outdoor Temperature

-30°C to 50°C

range

(-22°F to 122°F)

Resolution

0.1°C (0.2°F)

Signal frequency

433 MHz

Power

2 x CR2032 batteries

AC / DC adapter

 

 

 

REMOTE UNIT (THN132N)

 

L x W x H

92 x 60 x 20 mm

(3.6 x 2.4 x 0.8 in)

 

 

 

Weight

62 g (2.22 ounces)

Transmission range

30 m (98 ft) unobstructed

Temperature range

-40°C to 60°C

(-40°F to 140°F)

 

 

 

Power

1 x UM-4 (AAA) 1.5 V

batteries

 

 

 

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientifi c.com) to learn more about Oregon Scientifi c products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientifi c.com/service/ support

OR

Call 1-800-853-8883.

For international inquiries, please visit: www2.oregonscientifi c.com/about/international

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientifi c.com or on

Phase 1,41 Man Yue St.,

Hung Hom, Kowloon,

Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

Station Météo Design

Modèle:BAR210 / BAR210U / BAR210A

MANUEL DE L’UTILISATEUR

FR

VUE D’ENSEMBLE

ECRAN LCD

1

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

 

 

 

 

 

6

 

 

 

1.Icônes de prévisions météo

2.Indicateur de réception du signal de l’horloge

3.Affi chage de l’heure et de la température

4.Indicateur de communication du capteur extérieur

5.Indicateur de faiblesse des piles

6.Affi chage du fuseau horaire

FACE ARRIÈRE

1

2

1.Trous de ventilation

2.Prise de l’adaptateur

VUE DU BAS

1

4

 

2

5

3

 

 

6

1./ : Augmente / diminue les réglages ; active / désactive le signal de réception de l’horloge

2. RESET (REINITIALISER) : Réinitialise l’appareil aux réglages par défaut

3. AUTO ON / OFF: Sélectionne le mode d’alternance automatique

4. CLOCK : Règle l’heure et le mode d’affi chage

5.°C / °F: Sélectionne l’unité de température et le mode d’affi chage

6.Compartiment des piles

1.Indicateur LED

2.Trou de fi xation murale

3.Compartiment des piles

4.Fente RESET (Réinitialiser)

5.Bouton CHANNEL (Canal)

POUR COMMENCER

Les piles n’ont qu’une fonction d’alimentation de secours pour l’horloge. Si vous désirez utiliser continuellement le rétro éclairage de l’écran LCD, veuillez brancher l’adaptateur secteur. Assurez-vous que la prise soit facilement accessible.

Insérer les piles :

1.Ouvrez le compartiment des piles et insérez les piles en respectant les polarités (+/-).

2.Appuyez sur RESET (REINITIALISER) après chaque changement de piles.

indique que les piles de l’appareil principal sont faibles.

SONDE SANS FIL

La sonde transmet les informations à la station principale.

Installation du capteur extérieur :

1.Ouvrez le compartiment des piles.

2.Sélectionnez un canal puis appuyez sur RESET.

3.Fermez le couvercle du compartiment des piles.

4.Installez le capteur extérieur à 30 m maximum (98 pieds) de l’appareil principal à l’aide du support de table ou de la fi xation murale.

ASTUCE La gamme de transmission peut varier en fonction de plusieurs facteurs. Vous pouvez expérimenter plusieurs emplacements afi n d’obtenir les meilleurs résultats possibles.

REMARQUE Utilisez des piles alcalines pour un usage prolongé et des piles au lithium pour la consommation lors de températures inférieures au gel.

TRANSMISSION DES DONNÉES DU CAPTEUR

L’appareil principal recherchera immédiatement le capteur extérieur. L’icône de réception du capteur situé sur la zone du capteur à distance vous indique le statut de la transmission :

ICONE

DESCRIPTION

 

Appareil principal à la

 

recherche du capteur.

 

 

 

Un canal a été trouvé.

Les données du capteur sont en cours de réception.

et ‘’-- :-‘’

Le capteur est

introuvable.

REMARQUE Si le capteur n’est pas localisé, vérifi ez les piles, les obstructions possibles et l’emplacement du capteur à distance.

Pour obtenir de meilleurs résultats :

Ne placez pas le capteur directement face aux rayons du soleil ou en contact avec des matières humides.

Installez le capteur face à l’appareil principal en réduisant les obstructions possibles.

Placez le capteur directement vers le ciel, éloigné des objets métalliques et électroniques.

Installez le capteur à proximité de l’appareil principal pendant les périodes froides de l’hiver.

1.LED status indicator

2.Wall mount hole

BAR210 USA IM R3.indd 1

To enable / disable signal reception:

Press and hold to enable or to disable signal reception.

NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal.

Clock signal reception indicator:

batteries.

Images shown in this manual may differ from the actual

display.

When disposing of this product, ensure it is collected

separately for special treatment.

Placement of this product on certain types of wood

may result in damage to its fi nish for which Oregon

Scientifi c will not be responsible. Consult the furniture

manufacturer's care instructions for information.

The contents of this manual may not be reproduced

without the permission of the manufacturer.

Do not dispose old batteries as unsorted municipal

waste. Collection of such waste separately for special

the warranty card for this product) for all inquiries instead.

We

 

Name:

Oregon Scientifi c, Inc.

Address:

19861 SW 95th Ave.,Tualatin,

 

Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product

Product No.:

BAR210 / BAR210U / BAR210A

Product Name:

Weather Light

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,

SONDE SANS FIL

HORLOGE

RÉCEPTION DE L’HORLOGE

Ce produit est conçu pour synchroniser automatiquement l’horloge avec le signal radio.

BAR210 :

EU : Signal DCF-77 : dans un rayon de 1500 Km (932 miles) depuis Frankfort, Allemagne.

BAR210U:

UK : Signal MSF-60 : dans un rayon de 1500 Km (932

9/18/07 10:29:58 AM

Image 1
Contents Temperature Getting Started Power SupplyReset PrecautionsModification DE L’AFFICHAGE Régler L’HORLOGEPrévisions Météorologiques Température
Related manuals
Manual 8 pages 54.7 Kb

BAR210, BAR210U, BAR210A specifications

The Oregon Scientific BAR210U, BAR210, and BAR210A are innovative weather stations that represent a significant leap in personal meteorological technology. These devices cater to weather enthusiasts and professionals alike, offering an array of features and advanced functionalities designed to deliver precise weather data for daily planning and monitoring.

One of the standout features of these models is their ability to provide accurate real-time weather information. Equipped with a barometric pressure sensor, the BAR210 series tracks changes in atmospheric pressure and displays this data alongside temperature and humidity readings. This combination allows users to anticipate weather changes effectively, providing insights into potential storms or shifts in weather patterns.

The BAR210U, in particular, is designed for enhanced usability with its wireless capabilities. This model can receive data from external sensors, enabling users to measure outdoor temperature and humidity while monitoring indoor conditions simultaneously. The wireless transmission ensures that users can place the external sensor up to 100 meters away from the main unit, providing flexibility in data collection points.

All models in the BAR210 series feature a sleek, modern design that seamlessly integrates into any home or office environment. The clear LCD display is easy to read, showing essential data such as current temperature, humidity levels, and barometric pressure. The units often include backlighting to ensure readability even in low-light conditions.

Another notable characteristic is the ability to display historical weather data. The BAR210 series can record past weather trends, enabling users to analyze changes in temperature and humidity over time. This feature is essential for those interested in studying long-term weather patterns or making comparisons against previous years.

The BAR210, BAR210U, and BAR210A also come equipped with an alarm function that notifies users of extreme weather conditions, such as temperature fluctuations. This alert system is vital for safety, particularly for individuals in regions prone to sudden weather changes.

Additionally, the devices often incorporate a weather forecast feature that predicts future weather conditions based on current data trends. This predictive capability helps users plan their activities more effectively, ensuring they are prepared for shifting weather conditions.

In summary, the Oregon Scientific BAR210U, BAR210, and BAR210A models are exemplary weather stations that blend advanced technology with user-friendly features. With their accurate data collection abilities, wireless functionality, sleek design, and historical data tracking, they serve as valuable tools for anyone interested in monitoring weather conditions, making them indispensable for home use or professional applications.