Omega M3185/1098 manual Assembly 3.1 Battery Installation, RH31 Indicator Assembly, Key Operation

Page 8

SECTION 3 ASSEMBLY 3.1 Battery Installation

BATTERY EXCHANGE METHOD

1. How to open the case

The case can be opened by removing two screws on the rear panel of the case.

In this case, the case can be opened easily be pulling the hand strap in the open direction, while pressing the upper case.

2. How to remove the battery

Insert a screwdriver to the bottom of the battery connector while holding the battery connector by fingers, and disconnect the connector by pushing it upward.

3. Battery exchange

Connect the battery connector to the connector on the PC Board. In this case, a confirmation chime sounds to show the end of the exchange.

Never disassemble, short, charge, throw into a fire, or heat the used battery nor directly solder it to the battery body, otherwise a rupture accident or an electrolyte leak failure may occur.

4. How to close the case

Insert the battery cord to the guide of the upper case without protruding it out of the case. Mount the hand strap.

Fit the upper and lower cases to each other and fasten two screws.

3.2 RH31 Indicator Assembly

Slide the RH31 indicator into the vinyl case provided in order to protect the case during use. Plug in the probe that is best suited for your application (see Figure 2 above for probe selection). The temperature/humidity probes are plugged into the socket located on the top of the indicator. Be sure to line up the “keys” on each connector before plugging in the probe.

3.3 How To Switch From ˚F/˚C

1.Remove 2 back cover screws.

2.Jumper pins 1 & 2 for ˚C, pins 2 & 3 for ˚ F.

3.Put back lower case and tighten screws.

Cover

Screws

˚ C

˚ F

4.3 Key Operation

Names of keys Contents

ON-OFF The power supply is turned on by pressing this key once and turned off by pressing this key again.

A confirmation chime sounds after turning on the power supply, and the power supply turns off automatically after about 3 minutes.

For canceling the auto off function, press [ON-OFF] key together with [CLEAR] key.

A confirmation chime sounds three times.

For turning off the power supply, press [ON-OFF] key.

•CLEAR By pressing this key, a confirmation chime sounds, the display setting functions (hold, humidity operation selection) are canceled, and the unit returns to the initial condition.

When the memory function is provided, (1) data collection is stopped by press- ing this key halfway during data collection (2) data readout is stopped by press- ing this key halfway during data readout, and also (3) the unit is reset to the last settting by pressing this key halfway during the time setting.

•HOLD The measured values of temperature and humidity are held by press- ing this key and the unit is set to the measuring condition (the hold condition is canceled) by pressing this key once more.

During the hold of measured values, ˚ C(˚ F) flickers.

•SEL The indicating value is switched in the order of [relative humidity → dew point → wet-bulb temperature].

Relative humidity: %RH

Dew point: ˚C(˚ F)

Wet-bulb temperature: ˚C(˚ F) flickering

•READ Press this key for advancing the numeric stepwise when setting the present time or data collection time.

Press this key when transmitting collection data to the personal computer. •WRITE Press this key for switching the setting items such as year, month, day, hour, and minute when setting the present time and data collection time.

TROUBLESHOOTING Symptoms Check contents

No display appears – Problem 1

Are the indicator and temperature-humidity sensor connected to each other securely?– Check

Has the battery life come to an end? – Check Is the battery set correctly? – Check Display remains unchanged – Problem 2

Is the [HOLD] key pressed? (˚ C (˚ F) flickers in this case) – Check Measured values are abnormal – Problem 3

[Is the unit correct?] – Check

Bar display appears in the upper column. – Problem 4 [Over-range]

Bar display appears in the lower column – Problem 5 [Under-range]

5

10

Image 8
Contents Temperature PRESSURE, Strain and ForceFLOW/LEVEL Data AcquisitionUSA WARRANTY/DISCLAIMERReturn Requests / Inquiries Table of Contents Specifications IntroductionRH31 Meter RH31 SensorsInstructions to Disassemble the Humidity Probes RH31 HUMIDITY/TEMPERATURE AdjustmentHumidity Calibration KIT Precautions Humidity Sensor CleaningUnpacking Humidity CalibrationProbe Assemblies for the RH31 Assembly 3.1 Battery Installation RH31 Indicator AssemblyHow To Switch From ˚F/˚C Battery Exchange MethodOperating Instructions 4.1 Display Codes Operation MethodRS232 Communications MeasurementData Collection Data Read

M3185/1098 specifications

The Omega M3185/1098 is a sophisticated and highly regarded timepiece that showcases the perfect blend of traditional Swiss watchmaking craftsmanship and modern technology. Designed to cater to both watch enthusiasts and professionals, the M3185/1098 is revered for its precision, reliability, and aesthetic appeal.

At the heart of the Omega M3185/1098 is the exceptional Caliber 3185 movement. This Swiss automatic movement is renowned for its accuracy, boasting a remarkable chronometer certification from the Swiss Official Chronometer Testing Institute (COSC). With a power reserve of approximately 48 hours, the Caliber 3185 ensures that the watch remains functional and precise even after being worn for an extended period. Additionally, this movement features a date function that is easily adjustable, adding to the watch's practicality.

Incorporating advanced technologies, the Omega M3185/1098 features the innovative Co-Axial escapement. This revolutionary component reduces friction between the moving parts of the watch, which ultimately results in improved accuracy and longevity. The Co-Axial escapement minimizes the need for regular servicing, making it a favorite among adventurers and everyday users who appreciate low-maintenance yet reliable timepieces.

The design of the Omega M3185/1098 reflects a harmonious balance between elegance and sportiness. It typically features a stainless steel case that is both durable and lightweight, ensuring comfort during wear. The watch face is often adorned with luminous hour markers and hands, enhancing visibility in low-light conditions. This is complemented by a scratch-resistant sapphire crystal that protects the dial from potential damage.

Water resistance is a key feature of the M3185/1098, making it suitable for various activities, from swimming to snorkeling. With a water resistance rating of up to 300 meters, wearers can confidently engage in aquatic adventures without fearing damage to the movement.

In summary, the Omega M3185/1098 stands out as a remarkable timepiece, showcasing an impeccable blend of state-of-the-art technology and timeless design principles. The combination of the Co-Axial escapement, Caliber 3185 movement, and robust construction make it an ideal choice for anyone seeking a watch that exemplifies both style and functionality. Whether worn in a professional setting or during leisure activities, the M3185/1098 remains a testament to Omega's commitment to excellence in horology.