Omega Engineering OM8828, OM8800D, OM8829, OM88128 manual Alarm Setting

Page 21

ALARM SETTING

Setting up the High Alarm and the Low Alarm enables to activate the red LED flash of the Data Logger. (See Dia. G)

-High Alarm temperature defaults at 85oC.-Low Alarm temperature defaults at -40oC.

-High Alarm Relative Humidity defaults at 100% . -Low Alarm Relative Humidity defaults at 0% .

User simply select desired High value or Low value by scrolling up for increasing or down for decreasing .

NOTE: Hi/Lo humidity setting is only available for model OM8829. Select " oF ( w/ RH% alarm) or oC (w/RH% alarm) for Humidity alarm setting in degree F or degree C . (See Dia.F-1 )

Diagram F-1:

Alarm Setting

ALM LED Flashing activation for model OM8800D . If a Temperature is higher than HI setting or less than LO setting , ALM LED will flash every second until you download to a PC .

For models OM88128, OM8828 ,OM8829 , if a temperature is higher than HI setting or less than LO setting , ALM LED will flash per every sample interval , for example , if set to 3 seconds for an interval , ALM and REC LED will flash every 3 seconds until you download to a PC .

18

Image 21
Contents OM8829,AND Interface Page Index D eIdeal for Application IntroductionMaterial Supplied Features For model with LCD OM8828 or OM8829 Front ViewModel OM8828 / OM8829 LCD DisplayBattery Replacement Installation procedure Software InstallationKeyboard Actions for Cursor Main ScreenDrag a cursor to move it FAQ Why cant I see the movement by pressing above keys ?Actions by Offset Knob Zooming and Panning on GraphsDisplay Control Data record number or Time display selectionExample Retrieve FileDiagram B-2 Retrieve File Save File 77.6ExampleCOM PORT. Setup Logger Setting Schedule MagneticImmediate Loggers Clock Setting Alarm Setting Unit Setting Logger ID SettingData Table Sleep Mode SettingEdit Cell FAQ How can I restore the original text ?Data table pop-Up Menu Goto Find SortPage Copying and Pasting Statistics Diagram Maximum Diagram J Print Graph Diagram LGroup Files Diagram MDisplay Control Cursor Status Blank Logo Download Commands Diagram S Diagram R-1Display Control For X-Axis records Diagram S-1Diagram T-1 General Specification Temperature Datalogger Temperature / Relative Humidity Datalogger with LCD Display Q.Frequently Ask Question FAQ If the logger is not flashing , how should I do ?