Roberts Gorden CTH2-40 CTH2-60, CTH2-125 Standard Parts List Contents of the Burner Carton

Page 17

SECTION 5: MAJOR COMPONENTS

5.1 Standard Parts List

Table 1: Contents of the Burner Carton

Part No.

Description

CTH2-40

CTH2-60

CTH2-80

CTH2-100

CTH2-125

CTH2-150

CTH2-175

 

 

 

 

 

 

 

 

 

030XXXXX

Burner Assembly (Rate and Fuel Varies)

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

02568200

Gasket (Burner to Burner Tube)

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

130100NA

Installation, Operation and Service Manual

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

94273914

Hex Head Bolts 5/16-18 Rolok

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

96411600

Split Lock washer

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

91201708

Pipe Nipple (Black) 1/2” NPT x 4”

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

91317300

1/4" Quick Disconnect (Wire)

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

*91412200

Flexible Stainless Steel Gas Hose - 1/2" NPT (US Models Only)

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

*91412204

Flexible Stainless Steel Gas Hose - 3/4" NPT (US Models Only)

-

-

-

-

-

1

1

 

 

 

 

 

 

 

 

 

03051503

Turbulator Adapter

1

1

1

1

-

-

-

 

 

 

 

 

 

 

 

 

03051504

Turbulator Aluminized Steel

2

4

4

2

-

-

-

 

 

 

 

 

 

 

 

 

03051505

Turbulator Stainless Steel

1

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

*Canadian Models: Rubber (Type 1) Gas Hoses available as an accessory. See Page 40, Section 9.

Table 2: Contents of Core and Extension Packages

 

 

 

 

Core Packages

 

 

 

 

Extension Packages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Rolled

 

Aluminized

 

 

Hot Rolled

 

 

Aluminized

 

 

 

 

 

 

 

 

 

 

 

 

Part No.

Description

20'

30'

40'

10' 20' 30'

40'

10'

20' 30' 40'

10' 20' 30'

40'

 

 

(6m)

(9m)

(12m)

(3m)

(6m)

(9m)

(12m)

(3m)

(6m)

(9m)

(12m)

(3m)

(6m)

(9m)

(12m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91409300

Tube, Hot Rolled Steel, 10' (3 m)

1

2

3

-

-

-

-

1

2

3

4

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91409408

Tube, HT Aluminized, 10' (3 m)

-

-

-

-

1

2

3

-

-

-

-

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03051101

Burner Tube, ALUMI-THERM®Steel, 10' (3 m)

-

1

1

-

-

1

1

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03051601

Burner Tube, HT ALUMI-THERM®Steel, 10' (3 m)

1

-

-

1

1

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01312700

Coupling Assembly

1

2

3

-

1

2

3

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02750303

Standard Reflector, 8' (3.5 m)

3

4

6

2

3

4

6

2

3

4

6

2

3

4

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02750800

End Cap

2

2

2

2

2

2

2

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03090100

Tube and Reflector Hanger

3

4

5

2

3

4

5

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91907302

S-Hook

3

4

5

2

3

4

5

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03050010

Reflector Support Package (Strap, Wire Form, Screws)

2

3

5

1

2

3

5

2

3

4

6

2

3

4

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91107720

U-Clip Package

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90502700

Vent Adapter

1

1

1

1

1

1

1

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01318901

Tube Clamp Package

1

1

1

1

1

1

1

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number

CP20HRS

CP30HRS

CP40HRS

CP10ALUM

CP20ALUM

CP30ALUM

CP40ALUM

EXP10HRS

EXP20HRS

EXP30HRS

EXP40HRS

EXP10ALUM

EXP20ALUM

EXP30ALUM

EXP40ALUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Image 17
Contents Vantage Page Roberts-Gordon LLC Page Table of Figures Page Manpower Requirements Heater SafetySafety Labels and Their Placement California PropositionTop and Bottom Panel Label Placement Side and Back Panel Label Placement Wall Tag Installer ResponsibilityCorrosive Chemicals National Standards and Applicable CodesInches Centimeters Model Standard ReflectorONE Side Reflector C D Unapproved InchesFoot Deco Grille and Protective Grille National Standards and Applicable Codes Major Components Contents of Core and Extension Packages Standard Parts List Contents of the Burner Carton30’ 9m Heater Installation Typical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview Linear Heater Layout Overview Tube Clamp Package Installation Burner Tube Installation1 Coupling and Tube Assembly Coupling and Tube AssemblyTurbulator Installation 2 Coupling and Tube AssemblyBy a reflector, except for a U-Tube Reflector InstallationDescription Part Number Reflector Support Package 1 Reflector, U-Clip and Reflector Support InstallationWindow facing down Burner InstallationTube Configuration Optional Heater AccessoriesTube Heater Assembly Overview Tube Heater Layout Overview Tube Length 3 Reflector Joint Installation Elbow Package Configuration .2.1 Elbow Installation2 Elbow Installation Reflector Joint Detail 4 Reflector Joint Installation 5 Reflector Joint Detail2 Side Reflector Installation Reflector Side Extension .3.1 Bracket InstallationScr ews Distance a Extension 2 Frame Shield Installation3 Grille Installation 2 Grille End Cap InstallationUnited States Requirements General Venting RequirementsCanadian Requirements Unvented OperationVertical Venting Horizontal VentingUnvented Operation Tube Termination Length RequirementsCommon Sidewall Venting Vertical Ventilation 4 10 cm PipeCommon Vertical Venting Outside Combustion Air Supply Vertical Outside Air Supply for Single Heater InstallationHorizontal Outside Air Supply for Double Heater Installation Vertical Outside Air Supply for Double Heater InstallationGAS Piping Correct Positions Low Voltage Thermostat with One Burner WiringLine Voltage Thermostat Wiring Internal Wiring Low Voltage Thermostat Wiring with Multiple BurnersElectrical Connection to the Burner Ladder DiagramPre-Season Maintenance and Annual Inspection Operation and MaintenanceSequence of Operation To Shut Off HeaterVehicles and Other Vicinity of the HeaterObjects Vent PipeGas Line Safety LabelsBurner Observation WindowTroubleshooting LED Status Indicates Honeywell SmartValve II TroubleshootingTroubleshooting Flow Chart Troubleshooting Top View of Heater Manifold Gas Pressure SettingReplacement Parts Motor and Blower Assembly Blower Inlet Gasket Door Switch Description Part Number Dimensions General SpecificationsGAS Pressure AT Manifold Pipe ConnectionROBERTS-GORDON will not PAY for Limitations on Authority Representatives Warranty is Void ifPage Page Page
Related manuals
Manual 2 pages 5.59 Kb

CTH2-40 CTH2-60, CTH2-175, CTH2-150, CTH2-100, CTH2-80 specifications

Roberts Gorden is a reputable name in the field of heating and energy efficiency, and its CTH2 series of infrared radiant heaters—including the CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175—are a testament to innovation and quality. Designed for commercial and industrial spaces, these heaters provide effective and efficient heating solutions tailored to various needs.

The CTH2 series employs advanced infrared heating technology, which radiates warmth directly to objects and individuals in the space rather than heating the air. This method ensures rapid heat-up times and energy conservation, making the heaters ideal for workshops, warehouses, and other large areas where traditional heating systems may be inefficient.

One of the main features of the CTH2 series is its high thermal efficiency. The heaters convert a significant portion of the energy consumed into usable heat, resulting in lower operational costs and a reduced carbon footprint. The CTH2 models utilize durable components designed to withstand the rigors of industrial environments, ensuring longevity and reliable performance.

The CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175 models vary in output capacity and design, providing flexibility for different heating requirements. The maximum heat output ranges significantly among the models, with the CTH2-175 offering the highest thermal output, making it suitable for larger spaces or areas requiring immediate and intense heating. Conversely, the CTH2-80 is ideal for smaller areas or those that require less heat.

Installation versatility is another key characteristic of the CTH2 series. These heaters can be mounted from the ceiling or installed horizontally or vertically, accommodating different building layouts and operational needs. The heaters are also designed for easy maintenance, featuring accessible components to facilitate routine checks and repairs.

The CTH2 series incorporates safety features such as overheat protection and flame safeguard systems, ensuring safe operation even in busy industrial settings. Additionally, their sleek and modern design allows them to integrate seamlessly with existing infrastructure without detracting from the overall aesthetic of the space.

In conclusion, Roberts Gorden’s CTH2 series—including the CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175—represents a pinnacle of infrared heating technology. With their impressive efficiency, customizable output, versatile installation options, and robust safety features, these heaters are a reliable choice for any commercial or industrial heating requirement.