Quantum Data 802 quick start Enable Status Display, Calibrate

Page 10

Power-up Modes

Enable Status Display

This mode replaces the Format Knob List index number to the left of the format name on the LCD with three characters that show the status of the selected format. It also replaces the Image Knob List index number to the left of the image name on the LCD with image version number.

This mode is activated by holding down the indicated buttons on power up.

 

Image

 

 

Video Gate

 

 

 

Sync Gate

 

 

Outputs

 

STEP

R

 

G

B

 

ACS

 

DCS

DSS

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H31 D4C=DMT0660

V60 1=OutlineO

Left Character

AAnalog Video Format D Digital Video Format

Center Digit

44 Bits-per-pixel Depth

88 Bits-per-pixel Depth

Right Character

MMonochrome Video C RGB Color Video

Y Color Difference Mode

Note: The Format test image shows full details of all parameters of a format.

Calibrate

The generator has built-in hardware for calibrating the signal levels of the analog video outputs. No extra hardware or test equipment is re- quired. However, you may obtain slightly better results if three 75 ohm terminators are connected to one set of the Red, Green and Blue outputs.

The self calibration operation is initiated by holding down the indi- cated buttons on power up.

Image

 

 

 

V ideo Gate

 

 

 

 

 

Sync Gate

 

 

 

Outputs

 

STEP

R

 

G

B

 

 

 

ACS

 

DCS

DSS

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The LCD will show a calibration progress report. Any calibration error messages may indicate a hardware problem that requires repair of the generator. The generator will con- tinue to function but may have signal level errors in or more analog out- puts.

• 10 • Model 802 Series Quick Start Guide

Image 10
Contents Model 802 Series Making Connections USB GpibLvds Connector Pinout Chart Lvds Option Only DVI Connector Pinout Chart DVI Options OnlyVideo Connector Pinout Diagram Units with TV option Only Front Panel Controls and Indicators Normal Mode LCD Window InformationSpecial Operating Modes and Functions OverviewRemove All Modes Power up ModesInitialize w/Factory Defaults Use Old Format NamesDigital Friendly Mode Power-up ModesAnalog Friendly Mode Clone Must be exact same model and firmware Enable programmable keypad Serial Port ConfigurationEnable numeric keypad Set Gpib AddressEnable Status Display CalibrateRotate Video Color Type Special Key FunctionsToggle Analog / Digital Video Type Set Pixel DepthDDC Based Autoconfiguration High-bandwidth Digital Copy Protection Hdcp Testing Test MethodUsing a Computer for Control and Programming Video Generator Manager VGMVGM Format Editor VGM Image EditorVGM Sequence Editor VGM Sequence PlayerInstructions for Bitmap Picture Download Using a Computer for Control and Programming Updating Generator Firmware Advanced Programming MethodsQuantum Data, Inc Big Timber Rd Elgin, IL 802B, 802F, 802G