RedMax HB250 Operation, Starting Engine, Restarting Engine While Engine is HOT, Stopping Engine

Page 11

Operation

STARTING ENGINE

1.Rest the unit on a flat, firm place.

2.Pump the primer until fuel flows out in the clear tube.

3.Move the choke lever upward to close the choke.

Choke Lever

A CLOSE

B OPEN

4.Holding the blower handle, pull the starter rope with your right hand. (Throttle lever in idling position.)

NOTE

Avoid pulling the rope to its dead end or returning it by releasing the knob. Such actions can cause starter failures.

5.When the engine has started, move the choke lever gradually downward to open the choke.

6.Allow the engine to warm up for a half minute before starting operation.

RESTARTING ENGINE WHILE ENGINE IS HOT

1. When restarting the engine immediately after stopping it, leave the choke open.

2. If the engine won't start after several attempts, close the choke and repeat pulling the rope or remove the spark plug and dry it.

STOPPING ENGINE

Release the throttle lever to the idling position and press the stop switch (red button) until the engine comes to a complete stop.

NOTE

Except for an emergency, avoid stopping the engine while pulling the throttle lever.

ADJUSTING IDLE SPEED

1.When the engine tends to stop frequently at an idle mode, turn the adjusting screw clockwise.

Idle Adjustment Screw

NOTE

Warm up the engine before adjusting the idle speed.

11

Image 11
Contents HB250 Safety First Contents USE of Blower Safety PrecautionsOperator Working Condition Warning Avoid Chances of Damage Avoid Noise ProblemFammille DE Moteur 5KZXS.0254VWEM Symbols on the machineBlower Pipe Parts Location & SpecificationsAssembly Model HB250Recommended Mixing Ratio Gasoline 50OIL HOW to MIX FuelFuel For Your Engine LIFE, Avoid Fueling the UnitRestarting Engine While Engine is HOT Adjusting Idle SpeedOperation Starting EngineCleaning AIR Filter MaintenanceMaintenance Chart AIR CleanerSpark Arrester Replacement Plug is a NGK BPMR7ASpark Plug MufflerBefore Storing the Blower Troubleshooting guideProcedures to be Performed After Every 50 Hours of USE StorageParts List  16   17   18  Limited Warranty RedMax Garantie limitée