RedMax EBZ3050RH manual Maintenance

Page 12

EBZ3050RH

9. Maintenance

Maintenance, replacement, or repair of the emission control device and systems may be performed by any non-road engine repair establishment or individual.

 

 

Daily

Every

Every

Every

System/Compornent

Procedure

or

25 hours

50 hours

100 hours

 

 

Before use

after

after

after

 

 

 

 

 

 

Air Filter

Inspect/Clean

 

 

 

 

 

 

 

 

 

Fuel Leaks

Inspect/Replace

 

 

 

 

 

 

 

 

 

Fuel Filter

Inspect/Replace

 

 

 

 

 

 

 

 

Fuel Line

Inspect/Clean

 

 

 

 

 

 

 

 

 

Spark Plug

Inspect/Clean

 

 

 

 

 

 

 

 

 

Muffler

Inspect/Clean

 

 

 

 

 

 

 

 

 

Muffler Spark Arrester

Inspect/Clean

 

 

 

 

 

 

 

 

 

Cooling System

Inspect/Clean

 

 

 

 

 

 

 

 

 

Screws/Nuts/Bolts

Tighten

 

 

 

 

 

 

 

 

 

Cylinder Exhaust Port

Inspect/Clean

 

 

 

 

 

 

 

 

 

F13

F14

US-12

WARNING

Make sure that the engine has stopped and is cool before performing any service to the blower. Contact with rotating blower fan or hot muffler may result in a personal injury.

AIR CLEANER

Check the air cleaner every 25 hours of use or more frequently if used under dusty conditions. A clogged air filter may increase fuel consumption while cutting down the engine power. Never operate the blower without the air filter or with a deformed filter element because unfiltered dusty air may quickly ruin the engine.

CLEANING AIR FILTER:

1.Remove the air cleaner cover.

2.Use neutral detergent and warm water to clean the filter element. After cleaning, air dry the element completely.

3.Reinstall the filter.

Never forget to attach the screen. If the screen is not attached, the cleaner will not seal properly and the dusts come into the cylinder.

(1)Element

(2)Screen

FUEL FILTER

A clogged fuel filter may cause poor acceleration of the engine. Check periodically to see if the filter is clogged

F15

F16

with dirt. The filter can be taken out of the fueling port using a small wire hook. Disconnect the filter assembly from the fuel pipe and unhook the retainer to disassemble it. Clean the components with gasoline.

(1)Screen

(2)Element

(3)Holder

(4)Retainer

SPARK PLUG

The spark plug may gather carbon deposits on its firing end with reasonable use. Remove and inspect the spark plug every 25 hours and clean the electrodes as necessary with a wire brush. The spark gap should be adjusted to .025 in (0.6~0.7mm).

Plug manufacturers recommend replacing the plug twice a year to avoid unexpected plug failure in a job.

REPLACEMENT PLUG IS A NGK CMR7H.

IMPORTANT

Note that using any spark plugs other than those designated may result in the engine failing to operate properly or in the engine becoming overheated and damaged.

To install the spark plug, first turn the plug until it is finger tight, then tighten it a quarter turn more with a socket wrench.

Image 12 Contents
EBZ3050RH Contents Specifications Parts locationModel EBZ3050RH Symbols on the machine Emission ControlFor safe operation Before useFuel safety Avoid noise problemTransport StorageMaintenance DisposalSet up Blower TubesThrottle Lever Throttle CableWarranty FuelFuel Gasoline RequirementsHOW to MIX Fuel Recommended Mixing Ratio Gasoline 50 OIL For Your Engine LIFE, AvoidFueling the Unit Operation Maintenance Procedures to be Performed After Every 100 Hours of USE MufflerSpark Arrester Ignition Coil AIR GAP InspectionTroubleshooting guide StorageDisposal Before Storing the BlowerManufacturers Warranty Coverage Owners Warranty ResponsibilitiesWarranty Commencement Date What is CoveredEmission Warranty Parts List What is not CoveredHOW to File a Claim Where to GET Warranty Service