ProForm PFSB73930 Using the Hydrotherapy Spa, Wiring the Hydrotherapy SPA, Priming the Pumps

Page 10
Loosen this
Collar

Using the Hydrotherapy Spa

The hydrotherapy spa is designed to seat seven adults. The spa holds approximately 375 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.

WIRING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to operate with a 240 volt AC power source. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 45 amps. No other appliance should be on the same circuit. Test the GFCI before connecting the power cord to the spa. Connection of the spa to the 240 volt power source must be performed by a qualified, licensed electrician and must comply with all local, state, and federal electrical codes. Please refer to the instructions on the inside of the controller for informa- tion about connecting the spa to a 240 volt power source.

Once the spa is filled with water, the power can be turned on. Note: If this is the first time the spa has been turned on, or if the pumps have been drained, the pumps must be primed before the spa can be used.

PRIMING THE PUMPS

To prime the pumps, follow the steps below.

1.Remove the access panel (see ATTACHING AND REMOVING THE ACCESS PANEL on page 17).

2.Make sure all of the valves in the plumbing system are open to allow as much air as possible to escape from the plumbing and the controller dur- ing the filling process. Fill the spa to the level shown in step 5 on page 9. Use towels to soak up any water that leaks from the plumbing and pumps during the priming process.

3.Loosen the indi-

cated collar on one of the pumps

to vent the air from the pump.

Repeat for the

other pump. Allow a small amount of water

and air to escape from the pumps and related plumbing. Then, retighten the collars.

4.Turn the power on. The spa will begin an auto- matic priming sequence.

A countdown from “005” to “000” will appear in the display of the console.

Once the countdown has reached “000,” “Pr” will be displayed. “Pr” indicates that the controller is in the two-pump priming mode. This mode will last for four to five minutes.

5.As soon as “Pr” is displayed, push pump button 1 once to start the pump on low speed and then push the button again to switch to high speed. Repeat for pump button 2.

If water is not flowing from the jets after two min- utes, turn the power off. Important: Do not allow the pumps to run without priming for more than two minutes. Under no circumstances allow a pump to run without priming beyond the end of the four to five minute priming mode. Doing so may cause damage to the pump and cause the spa to go into an overheat condition.

Repeat the process of venting the air from the pumps and the controller and priming the pumps until water flows from the jets.

6.When the priming sequence is completed, the spa will automatically return to the normal heating and filtering mode. During the priming process, the heater is disabled to allow the pumps to be primed without activating the heater under low flow or no flow conditions.

Once the pumps are primed, push pump button 1 and pump button 2 to turn the pumps off.

7.The console will display “100F” and then “--F,” for approximately one minute. The spa requires one minute of water flowing through the heater to determine the water temperature.

10

Image 10
Contents Model No. PFSB73930 Serial No Customer HOT LineTable of Contents Posting the Warning SignImportant Safety Instructions Read and Follow ALL InstructionsPage Page Before You Begin If you set up the hydrotherapy spa outside If you set up the hydrotherapy spa insideChoosing a Location for the Hydrotherapy Spa Assembly Be careful not to damage the spa shellMolded fill line. Do not overfill the spa Wiring the Hydrotherapy SPA Using the Hydrotherapy SpaPriming the Pumps Securing the SPA Cover on the SPA Testing and Treating the WaterStarting the Hydrotherapy SPA Spa Shell Diagram Using the Controls Page Maintenance Sanitizing the Hydrotherapy SPA Water ChemistryMaintaining the Proper PH Balance Changing the Filter CycleScrews Attaching and Removing the Access PanelDraining the Hydrotherapy SPA Draining the Pumps Replacing the LED Light Winter USE and CareTroubleshooting Symptom the Water Level Drops Page Part List-Model No. PFSB73930 Qty DescriptionExploded Drawing-Model No. PFSB73930 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT