ProForm PFSB73930 user manual Troubleshooting

Page 19

Troubleshooting

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time.

1. SYMPTOM: THE SPA WILL NOT OPERATE

6. SYMPTOM: THE WATER DOES NOT HEAT

a. Check to see if the GFCI breaker is tripped or was not turned on. Reset the GFCI breaker.

2.SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SPA IS OPERATING

a.Reset the circuit breaker or the GFCI. If the cir- cuit breaker or the GFCI trips again, contact a qualified electrician for service.

3.SYMPTOM: THE PUMP HUMS

a.The filter may be dirty or damaged. Remove the filter from the filter housing and clean or replace the filter (see page 15).

b.The pump may have a foreign object stuck in the impeller. Contact our customer service department.

c.The pump may have a loose wire connection. Contact our customer service department.

4.SYMPTOM: THE PUMP HUMS, BUT DOES NOT ROTATE

a.The pump may be jammed. Contact our cus- tomer service department. If your spa is no longer under warranty, contact a local spa and pool service provider.

5.SYMPTOM: THE PUMP IS NOISY WHILE OPERATING

a.There may be debris in the pump. Contact our customer service department.

b.The pump may have a bad bearing. Contact our customer service department.

a. Make sure that the hydrotherapy spa is fully covered with the spa cover. The spa cover must be tight for the water to heat. Set the air control to low. The water will heat at a rate of 6°F per hour. If you are using the spa indoors and the room temperature is main- tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.

b. If you are using the hydrotherapy spa outdoors, it may take longer for the water to heat. See the chart below for the approximate heating time.

Air Temperature

Heating Time

70°F +

6 to 8 hours

50°F to 70°F

9 to 11 hours

30°F to 50°F

12 to 14 hours

b. If the water still has not heated after four days, contact our customer service department.

7.SYMPTOM: THE WATER IS NOT BEING CLEANED BY THE FILTER

a.Check to see if the filter are in place. Clean the filter if they are dirty.

b.Check the chemical balance of the water. If the pH is incorrect, the sanitizing agents will not function properly. See the section on maintain- ing the proper pH balance on page 16.

8.SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW

a.This usually occurs only when the water level is low. Add water until it is 2” to 4” above the skimmer basket.

b.The filter cover may not be tight. Make sure the filter cover is tight.

19

Image 19
Contents Customer HOT Line Model No. PFSB73930 Serial NoPosting the Warning Sign Table of ContentsRead and Follow ALL Instructions Important Safety InstructionsPage Page Before You Begin If you set up the hydrotherapy spa outside If you set up the hydrotherapy spa insideChoosing a Location for the Hydrotherapy Spa Be careful not to damage the spa shell AssemblyMolded fill line. Do not overfill the spa Wiring the Hydrotherapy SPA Using the Hydrotherapy SpaPriming the Pumps Securing the SPA Cover on the SPA Testing and Treating the WaterStarting the Hydrotherapy SPA Spa Shell Diagram Using the Controls Page Maintenance Changing the Filter Cycle Water ChemistryMaintaining the Proper PH Balance Sanitizing the Hydrotherapy SPAScrews Attaching and Removing the Access PanelDraining the Hydrotherapy SPA Winter USE and Care Draining the Pumps Replacing the LED LightTroubleshooting Symptom the Water Level Drops Page Qty Description Part List-Model No. PFSB73930Exploded Drawing-Model No. PFSB73930 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT