Refer to the console diagram above. The function of each console control is explained below:

Temperature: Controls the temperature of the water. The water heats at about 2.0¡F an hour with the cover on. The thermostat can be set to heat the water from 70¡F to 104¡F. Always use an accurate thermometer to check the temperature of the water.

Jets: Turns the thera-jets on and off. To turn the thera-jets on, press the control once. To turn the thera-jets off, press the control twice. After you press it once, the thera-jets will shut off for about 30 min- utes, and restart. Press the control again. The thera- jets will remain off. However, at any time after the

thera-jets have been shut off, the pump will begin cycling to heat the water if the temperature falls below the minimum setting. Note: To keep the heat cycle from running, the power cord must be unplugged.

Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase. If the control is turned to the right, the amount will decrease.

Heat On: This LED indicator is lit when the spa is run-

ning the heating cycle. Note: To suspend the heat- ing cycle, press the On/Off button once. The heat- ing cycle and massage jets will shut off, and will resume operation 30 minutes later.

Caution High Temp: This LED indicator will light if the water temperature exceeds 120¡F. Do not enter the spa. Add cold water to reduce water tempera- ture. You must unplug the power cord, and plug it back in to reset the spa; the spa will not operate until it has been reset. If the spa repeatedly over- heats, have it serviced by a qualified technician.

SPA JET OPERATION

C

B

AD E

B

Refer to the diagram above. The function of each spa jet is explained below:

The three uni-directional thera-jets (A), located on one end of the spa, focus the water massage on your back.

The three multi-directional thera-jets (B) can be adjusted for a custom hydro-massage. One of the jets is located below the three uni-directionalthera-jets and focuses the water massage on your lower back. Another jet, located near the floor, focuses the water massage on your legs. The remaining jet, located on the other end of the spa, focuses the water massage on your upper or lower back.

The filter (C) can be removed for replacement and cleaning (see CHECKING AND CLEANING THE FIL-

TER on page 13 for information on how to remove the filter from the spa).

.

The suction vent (D), located near the floor of the spa, brings the water into the pump, in order to oper- ate the system. The suction cover should always be in place over the suction vent. Never operate the spa without the suction cover in place.

This spa is ozone ready. An optional ozone generator can be installed to utilize the ozone jet (E). Ozone provides a way to help sanitize your spa with minimal chemical treatment.

The RESTORATION 2.0 features automatic freeze protection. If the water temperature falls below 40¡F, the pump will begin circulating and heating the water to prevent the water from freezing.

11

Image 11
Contents Mon.ÐFri., 6 a.m.Ð6 p.m. MST QUESTIONS?Model No Serial No Customer HOT LineLimited ONE Year Massage SPA Warranty Table of ContentsPage Page Page Before YOU Begin Do not use an extension cord with the Restoration If you set up the Restoration 2.0 insideIf you set up the Restoration 2.0 outside Choosing a Location for the Restoration Be careful not to damage the spa shell SET-UP and Assembly Tools Required for Assembly Mesh Pocket Starting the Restoration Using the RestorationTesting and Treating the Water Plugging in the RestorationSPA JET Operation Using the ConsolePosting the Warning Sign Using the Insulation BlanketSecuring the SPA Cover Maintenance Draining the Restoration Attaching and Removing the Access CoverWater Chemistry Maintaining the Proper PH BalanceWinter USE and Care Draining the PumpOpening and Closing the CUT-OFF Valves TROUBLE-SHOOTING Symptom the Water Level Drops Symptom the Water Pulsates or There is Minimum Water FlowSymptom the Water is not Being Cleaned by the Filter Qty Description Part LISTÑModel NoExploded DRAWINGÑModel No Model No Ordering Replacement Parts