ProForm 831.21002 user manual SET-UP and Assembly, Tools Required for Assembly

Page 8

SET-UP AND ASSEMBLY

Before beginning assembly, carefully read the following information and instructions:

¥Place all parts in a cleared area and remove the packing materials from the spa shell; do not dis- pose of the packing materials until assembly is completed.

¥Assembly requires two people.

¥Read each assembly step before you begin.

¥During assembly, make sure that all parts are ori- ented as shown in the drawings.

TOOLS REQUIRED FOR ASSEMBLY:

¥Your own phillips screwdriver

¥You may also need a hammer

1.Before beginning assembly, be sure that you have read and understand the information in the box above and on the previous page.

Remove the two cover screws from the access cover. Remove the access cover from the Spa Unit (15) by sliding the access cover down and pulling the bottom of access cover away from the Spa Unit.

Be careful not to damage the spa shell.

Remove the Power Cord with the GFCI (9) from inside the Spa Unit (15).

2.Locate and check the position of the cut-off valves. Occasionally the valves will be closed at the factory during manufacturing. The cut-off valves must be open for proper spa operation. To open the valves, hold one of the handles and turn the handle until you can pull it out to the open position. Open the other valve in the same manner. WARNING: THE

MOTOR WILL BE DAMAGED IF IT IS OPERATED WITH THE CUT-OFF VALVES CLOSED.

Close the valve knob on the drain hose. Thread the drain plug into the Pump Motor (11). Tighten the pump fittings.

Re-attach the access cover (not shown) to the Spa Unit (see step 1 above).

3.Wipe out the spa shell using a damp cloth. Remove the two warning decals (not shown) from the spa shell. Before you fill the RESTORATION 2.0, be sure that it is in the position you want, and that it can be easily serviced, if needed. Once the spa is filled with water, it must be drained to be moved.

Using a garden hose or other clean water source, begin filling the RESTORATION 2.0. The water tem- perature does not matter; however, if you use warm or hot water, the spa will be ready to use sooner. Fill the spa, until the water reaches the fill line. Do not overfill the spa.

1

 

 

 

 

15

Access Cover

Cover Screws

9

2

 

 

Cut-off

 

Cut-off

Valve

 

Valve

 

 

11

Drain

Pump

Valve

Plug

Fittings

Knob

 

 

 

Drain Hose

 

 

3

 

 

Fill to Here

 

8

Image 8
Contents QUESTIONS? Model No Serial NoCustomer HOT Line Mon.ÐFri., 6 a.m.Ð6 p.m. MSTTable of Contents Limited ONE Year Massage SPA WarrantyPage Page Page Before YOU Begin If you set up the Restoration 2.0 inside If you set up the Restoration 2.0 outsideChoosing a Location for the Restoration Do not use an extension cord with the RestorationBe careful not to damage the spa shell SET-UP and AssemblyTools Required for Assembly Mesh Pocket Using the Restoration Testing and Treating the WaterPlugging in the Restoration Starting the RestorationUsing the Console SPA JET OperationPosting the Warning Sign Using the Insulation BlanketSecuring the SPA Cover Maintenance Attaching and Removing the Access Cover Water ChemistryMaintaining the Proper PH Balance Draining the RestorationWinter USE and Care Draining the PumpOpening and Closing the CUT-OFF Valves TROUBLE-SHOOTING Symptom the Water Level Drops Symptom the Water Pulsates or There is Minimum Water FlowSymptom the Water is not Being Cleaned by the Filter Part LISTÑModel No Qty DescriptionExploded DRAWINGÑModel No Ordering Replacement Parts Model No