D4 Profoto D4 – Brief Instructions
For the above reasons we do not recommend mixing the use of Acute and ProHeads, especially on 230V markets, if you have a mixture of
The D4 is as default set to be compatible with Acute heads (Acu). If you wish to change the default setting please follow the procedure below:
1 . With the generator activated, disconnect the mains cable and any heads connected.
2 . Press and hold down the 3 centre buttons shown in the image below.
3 . Connect the power cable.
4 . Wait for the Aux function display (In the right hand corner) to display Pro. (It will first display which radiomodule (optional) is installed, then the default head configuration =Acu, then it will change to Pro) After “Pro” is displayed, 3 short beeps confirm the new setting.
5 . Release the 3 buttons and the generator is now configured for
If you need to check which default setting the D4 has, unplug the D4 generator when acti- vated (power on) then
WARNING: At
How to connect heads
One, two, three or four lamp heads can be connected to the sockets marked A, B, C and D [9]. When connecting the lamp head plug, align the white dots on the plug with the white dot on the generator panel. Secure by turning the locking ring on the plug clockwise. If the generator is connected to the mains, and turned on a green dot in the right corner of the Power Display(s) [10] will indicate that the head is connected properly. With Profoto’s special head connection it’s possible to plug and unplug heads safely even if the generator/outlet is activated.
Profoto | 20 | The Light Shaping Company |