MAINTENANCE
Gear housing
There are three grease nipples on the gear housing. Use a grease gun to top up with grease. This should be carried out approximately every 20 working hours. Use Husqvarna special grease, part no. 503 98
CAUTION! The gear housing must not be filled completely with grease. The grease expands as the machine heats up during operation. If the gear housing was completely filled with grease it could damage the seals and lead to leakage of grease.
The grease in the bevel gear does not normally need to be changed except if repairs are carried out.
Cleaning and lubrication
After you have used the machine clean any resin and plant residue from the blades using cleaning agent 531 00
Always lubricate the blade bars with special grease, part no. 531 00
Maintenance schedule
Below you will find some general maintenance instructions. If you need further information please contact your service workshop.
Daily maintenance
1 | 2 | 3 | 4 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 | 6 | 7 | 8 |
1Clean the outside of the machine.
2Check that the components of the throttle control work safely. (Throttle lock and throttle control.)
3Check that the stop switch works correctly.
4Check that the blades do not move when the engine is idling or when the choke is in the start throttle position.
5Clean the air filter. Replace if necessary.
6Check that the hand guard is not damaged. Replace the guard if damaged.
7Check that nuts and screws are tight.
8Check that there are no fuel leaks from the engine, tank or fuel lines.
Weekly maintenance
1 | 2 | 3 | 4 | 5 |
6 | 7 | 8 |
| 9 |
1Check the starter and starter cord.
2Check that the vibration damping elements are not damaged.
3Clean the outside of the spark plug. Remove it and check the electrode gap. Adjust the gap to 0.5 mm or replace the spark plug. Check that the spark plug is fitted with a suppressor.
4Clean the cooling fins on the flywheel.
5Clean or replace the spark arrestor mesh on the muffler (only applies to mufflers without a catalytic converter).
6Clean the carburettor compartment.
7Clean the cooling fins on the cylinder and check that the air intake near the starter is not blocked.
8Fill the gear housing with grease. This should be carried out approximately every 20 working hours.
9Check that the screws that hold the blades together are correctly tightened.
Monthly maintenance
1 | 2 | 3 | 4 |
5 | 6 | 7 | 8 |
1Clean the fuel tank.
2Clean the outside of the carburettor and the space around it.
3Clean the fan and the area around it.
4Check the fuel filter and the fuel hose. Replace if necessary.
5Check all cables and connections.
6Check the clutch, clutch springs and the clutch drum for wear. Replace if necessary.
7Replace the spark plug. Check that the spark plug is fitted with a suppressor.
8Check and clean the spark arrestor mesh on the muffler (only applies to mufflers fitted with a catalytic converter).