TROUBLE SHOOTING
Fault | Cause Analysis | Corrective Action | |
| Pressure washer not plugged in. | Plug in pressure washer. | |
| Circuit breaker has tripped or | Reset breaker or replace fuse. | |
When switch "I" the machine | fuse is blown. |
| |
will not sart working | "RESET" button on FGCI not | Push "RESET" button. | |
| pushed. |
| |
| The pump is stuck. | Turn the motor manually. | |
| Insufficient water supply. | Turn the motor manually. | |
| Adjusting valve seal is worn out. | Min inlet water pressure 20L/min. | |
|
|
| |
| Water inlet is clogged. | Check and /or replace new valve seal. | |
| Pump sucking air from | Clean the water inlet filter. | |
|
|
| |
Low water pressure or no | connections or hoses. | Check that connections and locking ring | |
water pressure |
| are well tightened. | |
| Leakage on water outlet. | wrench the water connector again. If | |
|
| necessary, change a new outlet hose. | |
| High pressure hose too long. | Use pressure hose less than 30 meters. | |
| Valve | change new | |
| The valves are dirty or blocked. | check, clean or replace new valve. | |
| Seal worn out. | Change water seal. | |
|
|
| |
| chemical filter is placed properly | make sure the chemical filter is placed | |
| in chemical. | lower than chemical. | |
Chemical injection system | chemical filter is clogged. | clean fliter. | |
not working |
|
| |
chemical too thick. | delute chemical with water. | ||
| |||
| chemical stocked in nozzle head. | clean the nozzle or replace new parts. | |
|
|
| |
| connect not connected well. | wrench the connector & make it connected | |
|
| tightly. | |
water leakage in pressure | water seal worn out. | Change water seal. | |
| |||
pump |
|
| |
pump housing and/or other parts | change parts. | ||
| broken. |
| |
| Nozzle being clogged. | check the nozzles. | |
| Pump sucking air. | Check that connections are airtight. | |
unstable pressure | Valves dirty, worn out or stuck. | Clean or replace. | |
|
|
| |
| Sealing worn out. | Check and replace. | |
|
|
| |
| Using an extension cord over 40 | Do NOT use extension cords over 40 feet. | |
| feet. |
| |
When you turn the switch | Pump is stuck due to dirt, mineral | Unplug unit. If temperature is below | |
| |||
ON, the engine buzzes, but | build up, or ice. | freezing do not use. Thaw in a warm area. | |
it does not start. |
|
| |
Net voltage is lower than the |
| ||
|
| ||
| minimum suggested voltage. | Check the electric installation is suitable. | |
|
|
|
17