PRECAUTIONS

This product is engineered to give you years of satisfactory service if handled carefully. Here are a few precautions:

Do not immerse the units in water.

Do not clean the units with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuits.

Do not subject the product to excessive force, shock, dust, temperature, or humidity, which may result in malfunctions, shorter lifespan, damaged batteries, and damaged parts.

Do not tamper with the units internal components. Doing so will invalidate the warranty and may cause damage. These units contain no user-serviceable parts.

Use only fresh batteries. Do not mix new and old batteries.

Read the user's manual thoroughly before operating the units.

SPECIFICATIONS

Main Unit

Indoor Temperature

Proposed operating range: 23.0°F to 122.0°F (-5°C to +50°C)

Temperature resolution: 0.2°F (0.1°C)

User-selectable (°F or °C) temperature display

Humidity (Indoor)

Operating Range: 30% to 80%

Resolution: 1%

Accuracy: 7%

Sampling Interval: 10 seconds

Clock

Precise atomic time 4 US Time Zones 12/24 hour time format

Crescendo 2 minutes alarm with 8 minutes snooze

Remote Sensor Remote Temperature

Proposed operating range with alkaline batteries: -40°C to + 50°C (-40°F to + 122°F) Temperature resolution: 0.1°C/ 0.2°F Sampling Interval: 10 seconds

Transmitting Interval: around 47 seconds

RF Transmission Frequency: 433 MHz

RF range: Maximum 164 feet (50 meters)

Temperature transmission cycle: approximately 45 seconds Low battery indicator (shown on the main unit’s display) Wall-mount or table stand

Power

Main unit: 2 CR2032 size 1.5V batteries (included)

Remote Sensor: 2 AAA size 1.5V batteries (not included)

Dimensions

Main unit: 7.01(L) x 4.72(H) x 0.37(D) inches/ 178(L) x 120(H) x 9.5(D) mm

Remote sensor: 1.48(L) x 4.33(H) x 0.91(D) inches / 37.5(L) x 110(H) x 23(D) mm

13

Image 13
Contents Page Introduction Before YOU Begin InstallationMounting FeaturesOperation PlacementMain Unit TimeFront Rear UP ? button Alarm buttonChannel button WALL- Mount holesTEMPERATURE/ Humidity Window Battery InstallationGetting Started Weather Forecast Remote Sensors StatusProgramming Temperature in Celsius or Fahrenheit Viewing Remote Channel TemperatureSetting Temperature Alarm Activating or Deactivating Temperature AlarmsCOM Comfort Level IndicationWET DRYClock Alarms Manual SettingsSetting the Weekday W and Single DAY S Alarms Time ZoneACTIVATING/ Deactivating Alarms Setting the ICE Warning Alarm PRE-ALCleaning Changing BatteriesSpecifications PrecautionsDeclaration of Conformity FCC StatementStandard Warranty Information Battery Safety InstructionsMeade Instruments Corp