Elation Professional AR-32RM manual Troubleshooting, Symptom Cause Resolution

Page 32

7.2 Troubleshooting

The AR-32 Architectural Recorder System should perform well when properly operated and maintained, however, sometimes things just don’t work like they should. Table 5 contains symptoms, causes, and resolutions for common faults.

Table 5

Symptom

Cause

Resolution

No Power

Bad power connection.

Check power connection.

 

 

Reconnect plug if needed.

 

No receptacle power.

Ensure receptacle has power.

 

Bad fuse.

Check fuse. Replace if needed.

Erratic Fixture

Improper DMX addressing.

Check and correct DMX

Behavior

 

addressing.

 

Improper DMX data cable.

Verify proper DMX data cable.

 

 

Replace if needed.

 

No DMX termination.

Properly terminate DMX data run.

No Control

Bad data connection.

Check all data cable connections.

 

 

Repair or reconnect as needed.

 

No power.

See No Power above.

 

Bad remote batteries.

Replace remote batteries.

 

Improper DMX addressing.

Check and correct DMX

 

 

addressing.

32

Image 32
Contents AR-32RM Table of Contents Customer Service Thank You for Purchasing the AR-32RM2-Year Limited Warranty General Information Gb Gigabyte ComplianceAbbreviations About AR-32RM Architecture Show System UnpackingMain Features Product DescriptionsManual Conventions Auto/Manual mode AR-32 Configuration Software OperationOperation on Remote Controller DMX Control Mode5-Pin XLR DMX Connectors Data Cable DMX Cable Requirements2 AR-32 Configuration Program Installation AR-32 IR Remote Controls Name DescriptionSoftware Overview Main ScreenManaging Flash Files Page Page Page Page Recording DMX Files Show Edit Screen Man aging DMX Files Page Page Configuring Shows Events Edit Screen Weekly Events Calendar Events Page DMX Files Programming TipsFlash Files Service MaintenanceTroubleshooting Symptom Cause Resolution