172988-YUM-A-0106

If, during the inspection of your furnace, you find any of the following conditions:

Excessive amounts of dust and lint on components.

Damaged or deteriorated components or surfaces.

Leaks or blockage in the vent pipe passages.

Water on any surface inside or outside of the furnace.

Do not operate the furnace, call a certified dealer / servicing contractor to check and / or clean your furnace, or for more information if you have questions about the operation of your furnace.

If all components appear to be in good operating condition, replace the front panels. Turn ON the gas and electrical power supplies to the fur- nace, and set thermostat to the desired temperature.

Motor Lubrication

The motors in these furnaces are permanently lubricated, and do not require periodic oiling.

SECTION II: SERVICE AND MAINTENANCE MANUAL

SAFETY

The following safety rules must be followed when servicing the furnace.

ELECTRIC SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death or property damage.

Improper servicing could result in dangerous operation, serious injury, and death or property damage.

Before servicing, disconnect all electrical power to the fur- nace.

When servicing controls, label all wires prior to discon- necting. Reconnect wires correctly.

Verify proper operation after servicing.

FURNACE MAINTENANCE

The furnace should be cleaned and adjusted by a certified dealer or qualified service contractor once a year or before the start of every heating season. The following items must be cleaned and serviced or replaced if there are signs of deterioration.

1.The vent terminal screen (if applicable).

2.The furnace vent and combustion air intake passageways. Should it be necessary to service the vent/air intake system, the manufac- turer recommends this service be conducted by a qualified service agency. The operation of this appliance requires the reassembly and resealing of the vent/air intake system.

3.The furnace burners, ignitor and flame sensor.

4.The condensate collection and disposal system. If any disassem- bly of components containing flue or vent gases is required, a qualified service agency must perform the service.

FURNACE CLEANING

NOTE: The cleaning operations listed below must be performed only by a qualified service agency.

Burner Removal/Cleaning

The main burners should be checked periodically for dirt accumulation. If cleaning is required, follow this procedure:

1.Turn off the electrical power to the unit.

2.Turn off the gas supply at the external manual shut-off valve and loosen the ground union joint.

3.Remove the burner door and remove the burner box cover.

4.Disconnect wires from flame sensor, rollout switch and HSI igniter. Remove igniter carefully, as it is easily broken.

5.Remove the screws that hold the burner box assembly to the vest panel and remove the assembly.

6.Remove burners from the burner assembly.

7.Burners may be cleaned by rinsing in hot water.

8.Reassemble the burners in the reverse order.

Cleaning the Heat Exchanger

1.Turn off the electrical power to the unit.

2.Turn off the gas supply at the external manual shut-off valve and loosen the ground union joint.

3.Remove the burner door and remove the burner box cover.

4.Disconnect wires from flame sensor, rollout switch and HSI igniter. Remove igniter carefully, as it is easily broken.

5.Remove the screws that hold the burner box assembly to the vest panel and remove the assembly.

6.Remove the vent pipe assembly, vent blower and condensate pan.

7.The heat exchanger is now exposed.

8.With a long flexible wire brush, clean inside each tube at both the top and bottom. The brush must pass around the rear heat exchanger tubes. Then vacuum loose the scale and dirt from each tube.

9.Replace all components in reverse order. Reconnect all wiring.

10.Restore electrical power and gas supply to the furnace.

11.Check furnace operation.

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing.

Cleaning the Secondary Heat Exchanger

1.Follow steps 1 - 7 under cleaning the Heat Exchanger.

2.Remove the vent piping from the vent blower housing. Disconnect the drain lines from the vent blower housing and from the conden- sate drain pan. Remove the vent blower housing blower and the condensate pan.

3.Using a stiff wire brush, remove the loose scale or soot from each tube.

4.Vacuum the secondary heat exchanger.

5.Finish the cleaning procedure by following steps 9 - 11 under cleaning the Heat Exchanger.

Cleaning the Vent / Air Intake System

Should it be necessary to service the vent / air intake system, the man- ufacturer recommends this service be conducted by a qualified service agency.

The operation of this appliance requires the reassembly and resealing of the vent / air intake system as specified in the “Combustion Air and Vent System” located in the Installation Manual.

NORMAL OPERATION SEQUENCE

The furnace control calculates the optimum firing rate each time the wall thermostat R and W contacts close or open (at the beginning and at the end of each call for heat) based on information from the thermo- stat and past demand. UNLIKE CONVENTIONAL SYSTEMS, THE WALL THERMOSTAT DOES NOT SIMPLY TURN THE FURNACE ON AND OFF. THE FURNACE CONTROL CALCULATES THE DEMAND AND MAY CONTINUE TO FIRE THE FURNACE DURING PORTIONS OF THE THERMOSTAT "OFF" CYCLE.

When the wall thermostat R and W contacts close, indicating a call for heat, the following sequence occurs:

Unitary Products Group

5

Page 5
Image 5
York PC9 Section II Service and Maintenance Manual, Furnace Maintenance, Furnace Cleaning, Normal Operation Sequence

PC9 specifications

The York PC9 is an advanced air conditioning system that has gained recognition for its efficiency and versatility in various applications. Specifically designed for both residential and commercial settings, it showcases a blend of innovative technologies, exceptional performance, and user-friendly features.

One of the standout characteristics of the York PC9 is its energy efficiency. Utilizing cutting-edge inverter technology, the unit can adjust its cooling output according to the specific needs of the space. This not only ensures optimal comfort but also significantly reduces energy consumption compared to traditional HVAC systems. The inverter compressor operates at variable speeds, which minimizes energy usage during partial load conditions—a critical feature for achieving cost savings and sustainability.

The York PC9 is equipped with advanced air filtration systems that enhance indoor air quality. These systems typically include multi-stage filters capable of capturing allergens, dust, and other airborne particulates. This makes the unit an excellent option for users with allergies or respiratory concerns, as it promotes a healthier indoor environment.

In terms of smart technology, the York PC9 often integrates seamlessly with home automation systems. Users can control their air conditioning via mobile apps or voice commands, allowing for convenient adjustments from anywhere. The smart features typically include programmable scheduling, remote temperature monitoring, and diagnostic capabilities that alert users to potential maintenance needs.

Moreover, the design of the York PC9 is both compact and aesthetically pleasing, allowing it to blend effortlessly into various settings. Its robust construction ensures durability, with weather-resistant materials that stand up to the rigors of different climates.

Another noteworthy feature of the York PC9 is its quiet operation. The units are engineered to minimize noise levels, ensuring that they do not disrupt daily activities in both home and work environments. This makes the PC9 especially appealing for bedrooms or office spaces where a serene atmosphere is essential.

In summary, the York PC9 embodies modern air conditioning technology with its energy-efficient inverter system, advanced air filtration, smart connectivity, and low noise levels. Whether for residential usage or commercial applications, it stands out as a reliable choice that combines innovative features with superior performance, catering to a wide range of comfort needs.