Dynacord DPA 4245, DPA 4260 owner manual Important Safety Instructions

Page 2

CONTENTS

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintan- ce (servicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a damp cloth.

7.Do not block any of the ventilation openings.

Install in accordance with the manufactures instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.

9.Only use attachments/accessories specified by the manufacturer.

10.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

For US and CANADA only:

Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrican for replacement of the absolete outlet.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times.

The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS - circuits have to be observed.

Note:

SAFETY COMPONENT (HAS TO BE REPLACED WITH ORIGINAL PART ONLY)

16

Image 2
Contents DPA 4245 / DPA 4260 Power Amplifier FeaturesImportant Safety Instructions Description Installation Notes Before The First OperationInstructions On How To Install NRS 90208 Extension Kits Inputs Input Channel A&BInput Routing Power Outputs A&BLevel Control Power Outputs Audio Transformer Outputs Power Outputs Isolated Outputs 70 V and 100Power Outputs Isolated Outputs 25 Power Outputs Direct OutputsBridged Mode Limit Indicator Ground Lift SwitchPower On And Remote Control Signal IndicatorProtection Circuitry Extension Kits For The DPA 4245 And The DPA Mains Operation And Leakage PowerFuses Technical Specifications DPA 4245, DPA DPA4245 DPA4260Bridged Mode
Related manuals
Manual 48 pages 1.34 Kb

DPA 4260, DPA 4245 specifications

Dynacord, a renowned name in professional audio equipment, has established a reputation for delivering high-performance amplifiers that meet the rigorous demands of live sound and installation applications. The DPA 4260 and DPA 4245 models stand out in their lineup, featuring advanced technologies and robust characteristics that set them apart in the competitive audio landscape.

The Dynacord DPA 4260 is a powerful four-channel amplifier that offers an impressive output of up to 2,600 watts, designed to drive a wide range of speakers effortlessly. One of its main features is the implementation of a sophisticated DSP (Digital Signal Processing) technology, which provides comprehensive control over audio parameters such as EQ, crossover, delay, and limiter settings. This allows users to optimize the sound output for various environments, ensuring clarity and fidelity in the audio performance.

In addition to DSP, the DPA 4260 is equipped with an advanced Power Factor Correction (PFC) system. This technology not only enhances the amplifier's efficiency but also ensures stable performance even under varying load conditions. The amplifier's robust build quality and efficient heat dissipation design make it suitable for extended operation in demanding venues.

On the other hand, the Dynacord DPA 4245 is another impressive model offering a slightly lower output of 1,400 watts but packed with its unique set of features. Like the DPA 4260, it benefits from the same DSP capabilities, allowing for detailed sound manipulation and tuning. This is particularly useful for sound engineers looking for precision in their audio setups.

The DPA 4245 also showcases versatility in its operation, featuring a selection of operating modes to accommodate different configurations, including bridge mode for driving larger loads. Its lightweight design makes it easy to transport and install without compromising on power or performance.

Both models come with comprehensive connectivity options, ensuring compatibility with various audio systems and setups, facilitating seamless integration into existing infrastructures. The front panel allows for easy monitoring, featuring LED indicators that display operational status and signal integrity.

In conclusion, Dynacord's DPA 4260 and DPA 4245 amplifiers exemplify cutting-edge technology and robust construction in the world of professional audio. With their powerful outputs, advanced DSP capabilities, and flexible configurations, these amplifiers are designed to meet the demands of professionals seeking reliable and high-quality audio solutions in live sound reinforcement and installation applications. Whether for touring, installations, or events, these amplifiers ensure a professional sound experience.