Honeywell TE529ELW, TS33 user manual F Switch, Before YOU Begin, Battery Installation Remote Sensor

Page 5

EWALL-MOUNT RECESSED HOLE Keeps the remote sensor on the wall

F°C/ °F SWITCH

Selects the temperature display unit in Celsius or Fahrenheit

BEFORE YOU BEGIN

1.We recommend using alkaline batteries for the main unit and remote sensor.

2.Avoid using rechargeable batteries.

3.Insert batteries before first use, matching the polarity as shown in the battery compartment.

4.Always install batteries in the remote sensor before the main unit.

5.Press RESET after each battery change, using a paper clip or similar tool.

6.During an initial setup, place the main unit as close as possible to the remote sensor.

7.After reception is established (remote temperature will appear on the receiver’s display), position the remote sensor

and main unit within the effective transmission range of

100feet.

NOTE:

1.Avoid setting the time and date on the main unit before the outdoor temperature is displayed.

2.The effective operating range may be influenced by the surrounding building materials and how the receiver and transmitter are positioned.

3.Position the remote sensor so that it faces the main unit (receiver), minimizing obstructions such as doors, walls, and furniture.

4.Though the remote sensors are weather-resistant, they should be placed away from direct sunlight, rain or snow.

BATTERY INSTALLATION

REMOTE SENSOR

NOTE: Install the batteries; select the channel and type of temperature (ºC/ºF) before you mount the sensor.

1.Remove the screws from the battery compartment with a small Phillips screwdriver.

2.Set the channel. The switch is located in the battery compartment. Channel 1 is typically selected if

7

only one remote sensor is being used.

3.If you are using more than one sensor, select a different channel for each sensor.

4.Install two “AA” size alkaline batteries (not included) matching to the polarities shown in the battery compartment.

5.Replace the battery compartment door and secure the screws.

6.Secure the remote sensor in the desired location.

BATTERY INSTALLATION

MAIN UNIT

1.Open the battery compartment door.

2.Install two batteries (UM-3 or “AA” size 1.5V) matching the polarity as shown in the battery compartment.

3.Replace the battery compartment door.

LOW BATTERY WARNING

A low-battery indicator [ ] will appear on the indoor or remote temperature reading line of the main unit warning that the corresponding batteries need replacement.

HOW TO USE THE TABLE STAND

The main unit has a removable table stand, which supports the unit on the flat surface. The main unit can also be mounted on the wall using the recessed screw hole.

The stand must be removed prior to mounting. The remote sensor can be similarly mounted or placed on a flat surface.

GETTING STARTED

After batteries are installed, remote sensors will transmit temperature readings at 45 second intervals. The main unit may take up to 2 (two) minutes to receive the initial readings. Upon successful reception, remote temperature will be displayed. Then the main unit will automatically update readings at 45-second intervals.

If no signals are received from the remote sensor(s) within

(2) two minutes, dashes “ ” will be displayed.

Press and hold [ ] button on the main unit for 2 seconds to initiate another signal search.

8

Image 5
Contents TE529ELW Introduction Product Overview Main Unit FeaturesAlarm ON/OFF Button Mode ButtonMemory Button UP ButtonRemote Sensor Features Battery CompartmentLED Indicator ResetBattery Installation Remote Sensor F SwitchBattery Installation Main Unit LOW Battery WarningTemperature Trends Maximum and Minimum Temperature & HumidityComfort Level Indicators Reading the Kinetic Wave DisplayLost Communications Weather ForecastAlarm Setting Clock Manually Time ZoneTransmission Collision Atomic ClockAlarms Disabling AlarmPrecautions SpecificationsFCC Statement Declaration of Conformity Standard Warranty Information

TE529ELW, TS33 specifications

The Honeywell TE529ELW/TS33 is a robust and versatile sensing device designed for a variety of industrial and commercial applications. Known for its reliability and precision, the TE529ELW is particularly suited for use in temperature monitoring, which is essential in maintaining optimal conditions in sensitive environments such as HVAC systems, food processing, and pharmaceuticals.

One of the standout features of the TE529ELW is its advanced temperature sensing technology. The device employs a high-accuracy thermistor, providing precise temperature readings with a minimal response time. This is crucial for applications that require rapid detection of temperature changes. The sensing range is extensive, accommodating various settings and ensuring it meets the demands of diverse environments.

The TE529ELW also incorporates a user-friendly design, making installation and calibration straightforward. Its compact form factor allows for easy integration into existing systems, while the robust construction ensures durability even in challenging industrial environments. Whether mounted on surfaces or enclosed within other equipment, the TE529ELW offers flexibility conducive to a broad spectrum of applications.

In terms of communication protocols, the TE529ELW is equipped with modern digital interfaces, allowing it to easily connect to control systems for data logging and monitoring purposes. This feature enhances operational efficiency by providing real-time feedback on temperature fluctuations, enabling prompt intervention when necessary.

Another key characteristic of the Honeywell TE529ELW is its resistance to environmental factors. The device is designed to operate effectively in high humidity and varying atmospheric conditions, which is essential in maintaining accuracy and reliability.

Overall, the Honeywell TE529ELW/TS33 is distinguished by its combination of precision, durability, and ease of integration, making it an ideal choice for businesses aiming to enhance their temperature monitoring capabilities. With its state-of-the-art sensing technology and robust features, it caters to a wide array of industries, ensuring optimal performance and reliability. Whether in industrial settings or commercial applications, the TE529ELW stands out as a dependable tool for effective temperature management.