GE DEH-211 manual Configuring the EPM Device Network, Running Network Builder

Page 54

Configuring the EPM Device Network

The PMCS installation routine described earlier in this manual creates initial workstation and software node entries in the EPM 7700 network configuration file. After EPM 7700 software components are installed, the next step is to add Ethernet sites and devices to the PMCS power-monitoring network using Network Builder software.

Running Network Builder

Network Builder software presents your EPM power-monitoring network graphically, showing the installed components in a hierarchical tree. Network Builder allows you to edit the Network Configuration file— the file that identifies every node in the EPM power-monitoring network.

The first step is to run Network Builder from the Start Menu: (Programs > Power Measurement Ltd > Utilities > Network Builder.)

The following figure shows how Network Builder displays a system comprised of the basic EPM software components, a single EPM 7700 meter, a Primary Node and a Stationless Secondary node (also called a ‘view node’).

Workstation: the network name of the

Primary Node computer running the

Communications Server and GE 7700.

Software nodes: Stationless Secondary nodes appear here.

Ethernet Site: Defines the Ethernet connection between the PMCS system and the connected device(s).

Device: Name(s) of attached device(s).

52 EPM Device- Special Considerations

CIMPLICITY PMCS Read-This-Book-First

Image 54
Contents Power Leader TM Enhanced MicroVersaTrip-C SR489 Generator Management Relay Back to Main Contents Configuring the Software How to Use this Book IntroductionWelcome Features About Cimplicity Pmcs VersionPerformance Cimplicity Pmcs Read-This-Book-First Introduction Supported Devices Device Firmware Revision SupportedPage Getting Started First StepsUnderstanding Terminology Cimplicity Pmcs Read-This-Book-First Getting Started Getting Started Cimplicity Pmcs Read-This-Book-First Where to Get Help System RequirementsWhat’s next? This page left blank intentionally Installing the Software Installing CimplicityComputer Preparation Installing Additional Software RS485 Pmcs Network InterfacesEthernet Pmcs Network Interfaces Local Area Network LAN Interfaces Installing the EPM Software Components Installing the Pmcs software ELicensing Pmcs softwareDay Trial Licensing via the WebHost PC Installation Viewer Workstation InstallationLicense by Phone Pmcs Installation Steps Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First At the Choose Destination Default is C. Click Next Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Installing the Software Cimplicity Pmcs Read-This-Book-First PQ Analyst Installation Steps Installing the Software Cimplicity Pmcs Read-This-Book-First Cimplicity Pmcs Read-This-Book-First Installing the Software Un-elicensing Pmcs Uninstalling Pmcs Uninstalling the Pegasys System Log ServiceInstalling the Software Cimplicity Pmcs Read-This-Book-First Reinstallation Steps Upgrading from previous versions to Pmcs Configuring the Software Organize Your InformationHost PC View Node COMConfiguration Procedure Host PC ConfigurationViewer Workstation Configuration EPM Software Components Configuration EPM Device Special Considerations IntroductionION Designer Programming Devices and Software Nodes Network Builder Building the Network Configuration FileEPM Software Components Communications Server System CommunicationsWorkstation Configuration Guidelines Configuring the EPM Device Network Running Network BuilderBuilding the Power-Monitoring Network in NetBuilder Adding a WorkstationAdding Software Nodes Adding an Ethernet Site Page Adding Devices Meters Saving and ExitingThis page left blank intentionally Using MMS Servers with Pmcs What is an MMS Server?Installation for Windows NT Preparing the MMS Server for use with Pmcs Page Page Page This page left blank intentionally Index GE Industrial Systems

DEH-211 specifications

The GE DEH-211 is a cutting-edge digital electro-hydraulic (DEH) control system developed by General Electric to enhance the performance and efficiency of hydroelectric and steam turbine operations. Notably recognized for its reliability and advanced features, the DEH-211 integrates modern technologies to facilitate precise control of turbine operations.

One of the main features of the DEH-211 is its robust digital architecture, which allows for real-time data processing and system monitoring. This digital platform enhances the overall performance by providing faster response times and improved signal processing, which are crucial for maintaining optimal turbine performance under varying operational conditions.

The DEH-211 employs advanced control algorithms that enable superior speed governing and load control. This results in increased stability and reliability for turbine operation, helping to achieve optimal efficiency levels. The DEH-211 also integrates advanced feedback mechanisms, ensuring that the system can quickly adapt to changes in load and other operational variables.

Another noteworthy technology integrated into the DEH-211 is its digital communication capabilities. The system supports various communication protocols that facilitate seamless integration with existing plant control systems and other digital devices. This flexibility allows operators to achieve a higher level of automation and centralize control processes, ultimately leading to reduced operational costs.

The DEH-211 is designed with redundancy in mind, which is crucial for applications where system availability is paramount. The system features dual processors and dual communication paths, ensuring that there is a backup in place should any component fail. This redundancy not only enhances reliability but also instills confidence among operators regarding safe plant operations.

Additionally, the DEH-211 has been engineered for ease of use. Its user-friendly interface allows operators to monitor and manage turbine operations efficiently. Features such as graphical displays and intuitive controls enhance accessibility, enabling operators to make informed decisions quickly.

In summary, the GE DEH-211 stands out in the realm of turbine control systems due to its advanced digital technology, precise control capabilities, and emphasis on redundancy and reliability. With its ability to integrate seamlessly with existing plant infrastructure and promote enhanced efficiency, the DEH-211 is a formidable asset for modern power generation facilities seeking to maximize their operational potential. This system not only meets the demands of today's energy landscape but also positions itself for future advancements in turbine control technology.