Harbor Freight Tools 95619 manual Operation

Page 10

Operation

1.Pick up the Spray Gun (37) and point it in a safe direction. Squeeze the Spray Gun

Trigger until all internal air is released, and a steady flow of water comes out. Then release the Spray Trigger.

2.Turn the Fuel Valve (D) to the open position (see engine photo).

3.Turn the Speed Control Lever (C) all the way to the left, or fast position (see photo).

4.Move the Choke Lever (B) all the way to the left, or closed position (see photo).

5.Pull the Starting Handle (A) (shown above in photo) lightly until you feel resistance. Then, pull it completely out. The engine should start up. If the en- gine does not start after a few tries, refer to Engine Manufacturer’s Trouble- shooting Tips. Slowly release the Starting Handle.

6.Adjust the Speed Control Lever (C) for the desired speed and subsequent output water pressure. Open the Choke Lever (B) to the right.

7.Hold the Spray Gun (37) with both hands and begin spraying. Do not allow the engine to run for more than three minutes without spraying.

SKU 95619 For technical questions please call 1-800-444-3353

Page 10

Image 10
Contents 95619 Safety Warnings and Precautions SpecificationsSave This Manual SKU 95619 For technical questions please call SKU 95619 For technical questions please call SKU 95619 For technical questions please call Unpacking Assembly Figure a Engine Setup Important Guidelines for Water SupplyOperation Cleaning Recommendations Turning Off the Pressure WasherCleaning Suggestions MaintenanceTroubleshooting Symptom Possible Cause SolutionAssembly Drawing Parts List Limited 1 year warranty