To Attach A Quick Connector:
1.Prior to use, the Pressure Blasting System requires the attachment of a Quick Connector (not included) to its Air Input Valve (14). To do so, make sure the screen Air Filter within the Valve Body is properly seated in the Valve Body. Wrap approximately 3” of Pipe Thread Seal Tape (47) around the male threads of the Quick Connector. Then, firmly tighten the Quick Connector into the Valve Body.
(See Figure F.)
QUICK CONNECTOR
(NOT INCLUDED)
AIR INPUT VALVE
(14)
FIGURE F
OPERATING INSTRUCTIONS
Abrasive Selection:
1.The type of media chosen will greatly influence the amount of time needed to clean a particular surface area.
2.Sandblasting media include silicon carbide, glass bead, walnut shell, brass bead, and alumina.
3.If you decide to reuse media, remember, it does wear out. The sharp edges become rounder and are less effective. At that point you should replace the tank of media you are using.
To Load Media Into The Tank:
1. WARNING! Never service the Pressure Blasting System or disassemble with the air hose attached. Always release any
SKU 93889 For technical questions, please call | PAGE 9 |