Wiring

Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite® must be properly grounded and bonded.

Input Power For stand alone operation:

Wire the Aqua Rite to the LOAD SIDE of the filter pump timer. It is very important that the Aqua Rite is powered only when the pump is running.

Refer to the wiring label on the Aqua Rite as well as the diagram below to determine correct wiring connections. The Aqua Rite is shipped from the factory with the configuration jumpers in 240VAC position. If using 120VAC, move the jumpers as shown below. For Canadian models, the Aqua Rite should be connected to a circuit protected by a class A ground fault interrupter. Be sure to connect the ground wire to the green ground screw terminal located on the bottom of the enclosure.

TYPICAL 240 VAC WIRING

120 VAC

 

TIMECLOCK

AQUA

AQUA

 

 

 

 

RITE

RITE

SUBPANEL

 

GND

GND

LINE

LOAD

 

 

 

 

PCB

PCB

GROUND

 

BONDING

 

 

 

 

 

 

LUG

 

 

PUMP

 

IMPORTANT:

 

 

MOVE JUMPERS

 

 

BONDING

TO POSITIONS SHOWN

LOOP

Note: Wire the pump directly to the timeclock--do not use the Aqua Rite as a junction box.

Bonding:

A lug used for bonding is attached to the bottom of the Aqua Rite enclosure (see diagram below). The Aqua Rite must be bonded with an 8 AWG copper wire (6 AWG Canada) to the pool bonding system.

Electrolytic Cell and Flow Switch:

The electolytic cell and flow switch cables are terminated with connectors which plug into the Aqua Rite, for easy attachment and removal. The door of the Aqua Rite must be open to access the cell cable connector. The flow switch plugs into a con- nector (similar to a telephone jack) located outside, on the bottom of the enclosure. Refer to the diagram below for the location of these connections.

Flow switch connector

Cutout for

cell cable

 

Bonding lug to

20 Amp Slow Blow Fuse

pool bonding system

 

11

Image 14
Contents Ldline Read and Follow ALL Instructions Table of Contents Bromine Water ChemistrySi = pH + Ti + Ci + Ai Saturation indexType of Salt to Use How to Add or Remove SaltSalt Level Pounds and Kg of Salt Needed for 3200 PPM Pounds and Kg of Stabilizer Cyanuric Acid Needed for 80 PPM Main Switch Indicator LEDsOperation Desired Output % adjustment knobSalt Display Winterizing Servicing and Cleaning the Aqua Rite cellMaintaining the Aqua Rite System Spring Start-upPreparing Pool/Spa Water Mounting the AquaRite ControlPlumbing Wiring Input Power For stand alone operationInput Power for use with JandyAquaLink RS Troubleshooting Low Salt LED illuminated or flashing Aqua Rite & Aqua Trol Limited Warranty Page Ldline