Input Power for use with JandyAquaLink® RS:
Wire the AquaRite® DIRECTLY to 120/240VAC power (not through timer or re- lay).
JANDY
AQUALINK RS
(120 VAC)
AQUA RITE | AQUA RITE |
(240 VAC) | (120 VAC) |
SUBPANEL
NEUTRAL
GROUND
GND
PCB
BONDING
LOOP
GND
PCB
BONDING
LOOP
Optional Jandy AquaLink RS:
The Jandy AquaLink RS and Aqua Rite use a 4 wire connection to communicate and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Locate appropriate screw terminals on the circuit board according to the diagram below (screw terminals are removable to aid in installation). IMPORTANT: Attach wires to like numbered screw terminal on both the Aqua Rite and AquaLink RS as shown in the diagram below. Refer to Jandy's instructions for proper wire connec- tion to the AquaLink RS.
4 | GREEN |
|
| |
3 | YELLOW |
|
| |
2 | BLACK | Jumper Installed | Jumper Removed | |
1 | RED | For Master | ||
For Slave(s) | ||||
|
| (Factory Default) | ||
|
|
|
Additional
Aqua Rite(s)
(if required)
Jandy | Jandy | Aqua Rite | Aqua Rite |
Controller | Power Center | (Master) | (Slave) |
Notes:
1.Never put more than 2 wires on a single terminal. Use the optional Jandy multi- plex PCB if necessary.
2.There must be only 1 "master" unit. All other Aqua Rite units must be config- ured as "slaves".
12