Graco Inc 1026, 800-717, 800-682, 800-654, 308-537, 2340, 1530 manual Set Up, Connect to Water Supply

Page 6

Set Up (2340)

If you are using a downstream chemical injector, install it between the pump unloader and the high pressure hose, using the quick couplers provided.

Connect the high pressure hose between the pump outlet and the gun inlet. Both of these connections are made with quick couplers.

CAUTION

Up to 100 ft (30 m) of high pressure hose may be used. Longer hoses may af fect sprayer performance, and chemical injector performance, if used.

Install the appropriate spray tip on the wand. See Installing and Changing Spray Tips. If you are using a sandblaster kit, see its separate manual for installation instructions.

Connect to Water Supply

CAUTION

Before attaching to the water supply, check your local plumbing code regarding cross–connection to the water supply . A backflow preventer , P/N 801–133, is available to prevent backflow of contaminated water into the fresh water supply . Install it upstream from the pump.

If inlet water pressure is over 60 psi (4.1 bar) a regulating water valve, P/N 800–258, must be installed at the garden hose connection.

Do not exceed 160 _ F (70 _ C) inlet water temperature.

Connect a hose with at least a 3/4 inch (19 mm) ID from the water supply to the unit’s 3/4 inch garden hose inlet. The supply hose should not be more than 50 ft (15 m) long.

NOTE: The water source at the unit

must have a

minimum flow rate equal to that of the unit (see Technical Data, inside back cover).

63￿￿￿53￿

Image 6
Contents HYDRA-CLEAN1026, 1530 Pressure Washers Spray Gun Safety Devices General SafetyPressure Relief Procedure Medical TreatmentFuel and Emission Hazards Hose SafetyEquipment Misuse Hazard System PressureMoving Parts Hazard TermsFor InstallationSet Up 1026 OnlySet Up Connect to Water SupplyStartup Trigger Safety Latch Chemical InjectorInstalling and Changing Spray Tips Follow the Pressure Relief ProcedureMaintenance SHUTDOWN, Flushing StorageTroubleshooting Chart ProblemParts Drawing Parts List Part Description QTYHydra-Cleanr2340 Pressure Washer Axle Pump and Unloader Assembly Crankcase Parts Drawing Parts List Pump Assembly, 2300 psi KIT Ring Pumping Section Pump ServiceValves Servicing the PlungersChassis & Wheels Assembly 800-719 1026 AccessoriesTechnical Data Servicing the V-PackingsGraco Warranty Important Phone NumbersGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN Parts Change Notice NEW