Karcher specifications Model K 1400 Overview Important Precautions Read First, Never

Page 2

K1400 electric 6/27/02 6/27/02 10:01 AM Page 2

Model K 1400 OVERVIEW

 

 

 

IMPORTANT PRECAUTIONS – Read First!

 

Item

Description

 

 

 

 

Safety Warnings

and do not yank on any cord to

 

1.

Power cord with Ground Fault Circuit Interrupter (GFCI)

 

 

 

 

 

 

 

disconnect. Keep cord away from heat

 

2.

Trigger gun

 

 

 

When using this product, basic precau-

 

 

 

 

and sharp edges. Always disconnect the

 

3.

Trigger gun safety lock

 

 

 

tions should always be followed:

 

 

 

 

extension cord from the receptacle before

 

 

 

 

Read all the instructions before using

 

4.

High pressure hose

 

 

 

disconnecting the product from the

 

 

 

 

 

the product.

 

5.

Water inlet with filter and

 

 

 

 

extension cord. If you are using an

 

 

 

 

High pressure jets can be dangerous

 

 

garden hose connector

 

 

 

extension cord, it should always be

 

 

 

 

 

 

if subject to misuse. The jet must not

 

6.

Retractable handle

 

 

 

 

completely unwound from the cable drum.

 

 

 

 

 

be directed at persons, animals,

 

7. Power cord holder (not pictured)

6

 

 

 

 

 

 

electrical devices, or the machine itself.

Ground Fault Circuit

 

8. Detergent suction tube with filter

 

 

 

 

 

 

 

9.

High pressure outlet

 

 

 

To reduce the risk of injury, do not

Interrupter (GFCI) Protection

 

10.

On/Off switch

 

 

 

 

operate the machine near children.

This product is supplied with a Ground

 

 

 

 

Learn how to stop the machine and

 

11. Spray wand extension (must be

 

 

Fault Circuit Interrupter (GFCI) built into

 

 

used for attaching accessories)

 

 

 

release pressure quickly. Be thoroughly

the power cord plug. This device provides

 

12.

Wash brush

5

 

 

 

familiar with the controls.

additional protection from the risk of

 

13.

Quattro-nozzle

 

 

Stay alert — watch what you are doing.

electric shock. If power is interrupted in

 

 

 

1

 

14.

Concentrated power

 

 

Wear safety goggles.

the line, the GFCI will automatically re-

 

 

cleaning tabs-sampler

10

 

 

Do not use acids,

close the circuit to the load after power is

 

 

 

 

 

restored. Depending on the GFCI model,

 

 

 

 

 

 

 

solvents, or any

 

 

 

 

 

 

 

it may be necessary to manually operate

 

 

14

 

 

 

 

flammable material in this product.

 

 

 

 

 

 

the reset button to restore power to the

 

 

 

 

 

 

 

These products can cause physical

 

 

 

 

 

 

 

GFCI load circuit. If replacement of the

 

 

 

 

 

 

 

injuries to the operator and irreversible

 

 

 

 

 

 

 

plug or cord is needed use identical

 

 

 

 

 

 

 

damage to the machine.

 

 

 

 

 

 

 

replacement parts.

 

 

 

 

 

 

• Do not operate the product when

 

1

 

 

 

 

 

2

 

 

 

 

 

fatigued or under the influence of

This Product Is

 

 

 

 

 

 

 

 

 

8

 

 

 

alcohol or drugs.

Double Insulated

 

 

 

 

 

Keep operating area clear of all

 

 

13

9

 

 

In a double-insulated product, two

 

 

 

 

 

persons.

 

 

 

 

 

 

 

systems of insulation are provided instead

 

 

 

 

 

 

Do not stand on unstable surfaces.

 

 

 

 

 

 

of grounding. No grounding method is

 

 

 

 

 

 

 

Stand with both feet balanced at all

provided on a double-insulated product,

 

 

 

 

 

 

 

times.

nor should a method for grounding be

 

 

 

2

3

4

To reduce the risk of electrocution, keep

added to the product. Servicing a double-

 

 

 

 

 

 

 

all connections dry and off the ground.

insulated product requires extreme care

 

 

 

12

 

 

 

Do not touch plug with wet hands.

and knowledge of the system, and should

 

 

 

 

 

• The Gun Safety Lock PREVENTS

be done only by qualified service

 

 

11

 

 

 

personnel. Replacement parts for a

 

 

 

 

 

 

the trigger from accidentally being

 

 

 

 

 

 

 

engaged. This safety feature DOES

double-insulated product must be

 

 

 

 

 

 

 

identical to the parts they replace. A

 

NEVER!

 

 

 

 

NOT lock trigger in the on position.

 

 

 

 

 

double-insulated product is marked with

 

 

 

 

Extension Cords

 

 

 

 

 

 

the words, “DOUBLE INSULATED.”

 

Never point nozzle at people or animals.

 

 

Use a sufficient gauge: Up to 25 ft = 12/3

Caution

 

 

 

AWG; 25 to 50 ft = 10/3 AWG. Use only

 

 

 

 

 

 

 

Never drink alcohol or use drugs while operating this equipment.

 

 

extension cords that are intended for

• Follow the maintenance instruc-

 

 

 

 

 

 

outdoor use. These extension cords are

 

 

 

 

 

 

tions specified in the manual.

 

Never operate while standing in water.

 

 

identified by the marking “Acceptable for

 

 

 

• This machine has been designed

 

 

 

 

 

 

use with outdoor appliances; store indoors

 

 

 

 

 

 

for use with cleaning detergent

 

Never touch plug with wet hands.

 

 

while not in use.” Use only extension

 

 

 

supplied or recommended by the

 

 

 

 

 

 

cords having an electrical rating not less

 

Never let electrical connections rest in water.

 

 

manufacturer. The use of other

 

 

 

than the rating of the product. Do not use

 

 

 

cleaning detergents may affect

 

 

 

 

 

 

damaged extension cords. Examine

 

Never operate pressure washer without the water turned on.

 

 

the operation of the machine and

 

 

 

extension cord before using and replace if

 

 

 

void the warranty.

 

 

 

 

 

 

damaged. Do not abuse extension cord

 

Never use hot water.

 

 

 

 

 

 

 

 

 

 

 

 

Image 2
Contents High Pressure Washer Operator Manual Model K 1400 Part NoModel K 1400 Overview Important Precautions Read First NeverAttached to use accessories Important Precautions Assembly InstructionsAssembly Instructions Operating InstructionsWorking with Detergents Install the Wash brush or Quattro nozzleOperating Instructions Gfci InstructionsTaking a BREAK... five minutes or more Shutting Down & CLEAN-UP Maintenance InstructionsCleaning Tips Winterizing and LONG-TERM StorageOptional Cleaning Accessories Cleaning TipsTroubleshooting Troubleshooting