STARTING

Prior to starting, refer to your engine manual for proper starting procedures for your engine type.

1.In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine Owners Manual for correct procedure.

2.Check engine oil level. See Engine Owners Manual for correct procedure.

NOTE: There will be a slight amount of oil in the engine from factory testing.

3.Verify the filter screen is in water inlet of pump. NOTE: Cone side faces out.

4.Connect water source to pump inlet.

NOTE: Water source must provide a minimum of 5 gallons per minute at 20 p.s.i.

5.Connect high pressure hose to pump outlet.

6.If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning Solvents in Operation section of this manual.

Filter Screen

 

 

 

 

 

 

7.

To reduce operator fatigue while maintaining

High

 

 

a consistent distance from the cleaning

Pressure

 

 

surface assemble the 'Water Vroom"

Hose

 

 

 

 

 

 

 

cleaning surface guide. See Assembly

 

 

 

 

 

section for assembly instructions.

 

 

 

 

8.

Turn water source on. NOTE: Failure to do

 

 

 

 

 

so could cause damage to the pump.

 

 

 

 

9.

Start engine. See Engine Owners Manual

 

 

 

 

 

 

Water

 

 

for correct procedure. NOTE: If the engine

 

 

 

 

 

 

Source

 

 

does not start after two pulls, pull the trigger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to relieve the pressure.

 

 

 

 

10.Depress trigger on gun to start water flow. NOTE: Stand on a stable surface and grip gun/spray wand firmly with both hands. Expect the gun to kick when triggered.

NOTE: If using the "Water Vroom" surface cleaning guide, quickly and effortlessly guide it across the flat surface being cleaned.

11.Release trigger to stop water flow.

12.Adjust spray for the task being performed by changing quick connect nozzle. See How To Use Spray Wand instructions in this section.

SHUTTING DOWN

1.After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. NOTE: Failure to do so could cause damage to the pump.

2.Turn engine off. See Engine Owner’s Manual. NOTE: NEVER turn the water off with the engine running.

3.Turn water source off.

4.Pull trigger on spray gun to relieve any water pressure in hose or spray gun.

5.See Storage section in this manual for proper storage procedures.

15- ENG

D28609

Image 15 Contents
Instructio N M Anual Consumer Safety Information Safety Guidelines DefinitionsImportant Safety Instructions Risk of Explosion or FireRisk to Breathing Risk of Chemical Burn Risk of Fluid InjectionRisk of Unsafe Operation Risk of Electrical ShockRisk of HOT Surfaces Risk of Injury from Spray Consumer General and Service InformationCarton Contents Assembly Instructions ENG D28609 D28609 ENG Basic Elements of a Pressure Washer Operating InstructionsBasic Elements of Engine Pressure Washer Operating FeaturesTo USE Spray Wand Read and Understand ALL Warnings Before Starting Unit HOW to Apply Chemicals and Cleaning SolventsShutting Down StartingMaintenance Nozzle CleaningEngine Pump HOW to Clean the Water Inlet Filter Storage Trouble Shooting Guide ProblemCausecorrection Chemicals Problem Cause CorrectionENG D28609 Warranty