PRE-START PREPARATION
Before starting the pressure washer, check for loose or missing parts and for any damage which may have occurred during shipment.
Handle Installation
Slide handle assembly onto handle supports. Align bolt holes and install 1/4” x 1 1/4” bolts and 1/4” nyloc nuts and tighten securely.
START-UP PROCEDURE
1.Make sure water supply is connected and turned on.
2.Release gun safety if locked.
3.To allow air to escape from the hose, squeeze trigger on the gun until there is a steady stream of water coming from the nozzle.
4.Remove any dirt or foreign matter from the gun outlet and the male connector of the wand.
5.Insert the nozzle wand into the gun wand and tighten the fitting securely.
STARTING THE ENGINE
Primer bulb
1.Check oil and fuel level.
2.Set the engine switch to the “ON” position.
3.Push the primer as necessary.
4.Squeeze trigger on pressure washer to release pressure while pulling on the engine starter rope with a fast steady pull. Pressure may otherwise build up making starting the unit difficult.
OPERATING CONNECTIONS
RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Up to 3600 GPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2GPM Maximum Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . .1800psi Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5oz.
HIGH PRESSURE/LOW PRESSURE
The high pressure nozzle position is intended for clean- ing. When high pressure is required, grasp collar and slide the collar and nozzle toward the gun.
NOTE: Make sure the nozzle cover is pulled to the extreme rear position to lock the nozzle in the high pres- sure position.
High Pressure
Low Pressure
When low pressure is required, grasp and slide the nozzle cover away from the gun.
ADJUSTABLE SPRAY NOZZLE
The adjustable spray nozzle can adjust spray from fan to pencil point in both the high and low pressure positions. The spray is adjusted by turning the nozzle cover.
FanSpray
To increase angle to a fan spray, turn counterclockwise.
HIGH PRESSURE HOSE
Attach the high pressure hose to the fitting located on the front side of the side panel. Only Coleman Powermate Pressure Washer high pressure hoses should be used.
WATER CONNECTION
Before connecting the inlet hose to the unit, run water
through the garden hose (not supplied) to flush out any foreign matter. The inlet hose will be connected to the fitting located on the back of the side panel.
English
Pin Point Spray
To decrease angle to a pencil point spray, turn clockwise.
CAUTION: The pencil point spray adjustment is very aggressive. We recommend that for most cleaning applications, a twenty degree (20°) spray angle be used to avoid damage to the surface being sprayed.
5