Laarsen Associates LG, LD operation manual 1B. Description, 1C. Warranty, 1D. Technical Assistance

Page 4

Page 2

WATERPIK TECHNOLOGIES INC.

 

 

Gas-Fired Pool Heaters, ANSI Z21.56, and in Canada with CAN1-4.7-M85.

Certain sections of this manual are specific to either United States or Canadian installations, and are labeled as such.

1B. Description

The Laars Lite 2 LD heater gets electrical power from an external 120VAC or 240VAC source and provides a dual thermostat Flex-Temp control system for pool/spa combinations or preheat convenience. The Laars Lite 2 LD heater also meets the California, New York, Hawaii, and Oregon state energy requirements for intermittent ignition gas appliances. The Laars Lite 2 LG heater is a self contained standing pilot unit and requires no external power.

The Laars Lite 2 heater is specifically designed for heating swimming pools and spas. Do not use it as a general service water heater. There is a specially designed model of Laars Lite 2 for heating salt water pools. Consult your dealer for the appropriate Waterpik Laars products for these applications.

1C. Warranty

The Laars Lite 2 heater is sold with a limited factory warranty. Details are specified on the back cover of this manual. A copy of the warranty and a warranty registration card are included in the plastic bag shipped with the heater. Fill out and return the warranty registration card.

Make all warranty claims to an authorized Waterpik Laars representative or directly to the factory. Claims must include the heater serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty cover- age.

Damage caused by improper installation or assembly, or to the heat exchanger by corrosive water, is NOT covered by the Warranty. See Section 3D for maintaining proper pool water chemistry.

NOTE: Keep this manual in a safe place for future reference when inspecting or servicing the heater.

1D. Technical Assistance

Consult Waterpik Laars or your local distributor with any questions or problems involving the specifica- tions, installation, and operation of your Waterpik Laars equipment. An experienced technical support staff is ready to assist in assuring the proper perfor- mance and application of Waterpik Laars products. For technical support call (415) 382-8220 extension 260.

SECTION 2.

Installation Instructions

2A. General Information

Install the Laars Lite 2 heaters, vent caps and drafthoods in accordance with the procedures in this manual, local codes and ordinances, and in accordance with the latest edition of the National Fuel Gas Code, ANSI Z223.1. In Canada, the installation must be in accordance with CAN1-B149.1 or .2 and local codes. The authority having jurisdiction may require that the installation conform to the Standard for Gas-Fired Heaters, ANSI Z21.56. Any changes to the heater, gas controls, gas orifices, wiring, draft diverter, or im- proper installation may void the warranty. If field conditions require change to any of the above, consult the factory.

All gas-fired products require correct installation to assure safe operation. The requirements for pool heaters include the following:

1.Field assembly (if required)

2.Appropriate site location (clearances) and flooring

3.Sufficient combustion and ventilation air

4.Properly sized gas meter and piping

5.Proper electrical wiring (if required)

6.Adequate water flow

This manual provides the information needed to meet these requirements. Review all application and installation procedures completely before continuing the installation.

2B. Field Assembly

The Laars Lite 2 heater is shipped from the factory with the top assembly in the low-profile configuration for outdoor installation in the U.S. In Canada, an outdoor installation requires the addition of a factory approved vent cap. The Laars Lite 2 heater is design certified for indoor installation when equipped with a drafthood, which must be installed without modification.

The Laars Lite 2 heater is also certified for installation in an outdoor shelter in Canada when equipped with a drafthood. An outdoor shelter is an enclosure not normally occupied which does not communicate directly with occupied areas.

Check the rating plate on the heater or the Parts List (Sec. 4) of this manual for the correct Waterpik Laars drafthood or vent cap part number. See instruc- tions supplied with the drafthood or vent cap for installation and attachment. When the drafthood is used, locate the heater so as to be in the same atmo- spheric pressure zone as the combustion air inlet to the heater.

Image 4
Contents Installation Laars Lite Pool and Spa Heater Outdoor Use OnlyTable of Contents Section 1A. Introduction1C. Warranty 2B. Field Assembly1B. Description 1D. Technical Assistance2C-1. Installation Information 2C. Site Location2C-2. Outdoor Installation 2C-3. Flooring Typical Installation2C-4. Indoor and Outdoor Shelter Installations United States2E. Gas Supply and Piping 2D. Combustion and Ventilation Air Supply2E-1. General Instructions 2E-2. Special Precautions for Propane Gas 2F. Electrical Wiring2F-1. General Information LD Only Model LD Wiring Diagram 2F-2. Auxiliary Time Clock Wiring Onnection Iagram2G. Water Flow System 2G-1. Flange Installation2F-3. Remote Operation Model LD Only Piping installation 2G-2. Reversible Water ConnectionsFlue collector hold-down brackets 2G-3. Check Valve Installation 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals2G-4a. Water Chemistry 2G-6. Adjusting the Pressure Switch2G-5. Pressure Relief Valve 2G-8. Temperature Rise 2G-7. Automatic Flow Control Valve2G-9. Adjusting the Manual Bypass Valve Typical installation3B. Lighting and Shutdown Procedures 3C. Setting the Temperature Control3A. General Information 3B-1. Model LD see 3B-2. Model LG see3B-1. Model LD Direct Ignition Do not try to light any appliance3B-2. Model LG Standing Pilot What to do if YOU Smell GAS3D. Seasonal Care 3D-1. Spring and Fall Operation3D-2. Winterizing 3D-3. Spring Start-up3E. Water Chemistry 3F. Spa/Hot Tub Safety Rules3G. Swimming Pool Energy Saving Tips 4B. Parts List 3H. Periodic Inspection4A. General Information 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Laars Lite Limited Warranty

LG, LD specifications

Laarsen Associates is a reputable engineering and consulting firm known for its innovative solutions in the field of energy and environmental management. Among its notable offerings are the LG and LD series of products, designed to optimize energy efficiency and reduce environmental impact in various applications.

The LG series focuses on providing high-performance tools for efficient energy management in commercial settings. These tools are engineered to integrate seamlessly into existing infrastructures, allowing businesses to monitor, control, and optimize their energy consumption effectively. One of the main features of the LG series is its user-friendly interface, which provides real-time data on energy usage, enabling users to make informed decisions quickly. Furthermore, the enhanced connectivity options facilitate remote access, allowing users to manage their systems from anywhere, significantly improving flexibility and response times.

On the other hand, the LD series is tailored for industrial applications, emphasizing durability and robust performance. The LD products are designed to withstand the harshest environments while maintaining consistent efficiency. Their advanced monitoring systems provide detailed insights into energy consumption patterns, allowing for predictive maintenance and reduced operational costs. Key characteristics of the LD series include high reliability, modular design, and adaptive technologies that can be customized to suit specific industrial requirements.

Both series employ cutting-edge technologies to achieve optimal performance. Smart sensors collect real-time data, which is processed using advanced algorithms to deliver actionable insights. These insights can lead to optimized processes, reduced energy wastage, and enhanced sustainability measures. Moreover, the integration of IoT capabilities allows for smarter energy systems that adapt in real time to changing conditions.

Sustainability is at the core of Laarsen Associates’ offerings. Both the LG and LD series are designed with a commitment to reducing carbon footprints and complying with global standards for environmental protection. Their features not only promote energy efficiency but also support clients in achieving their sustainability goals.

In conclusion, Laarsen Associates’ LG and LD series represent the forefront of energy management and environmental solutions. With their combination of user-centric design, advanced technology, and commitment to sustainability, these products pave the way for businesses and industries to navigate modern energy challenges effectively.